Page 56
NOTE: IF ENT X TONE AND ENT X LATCH ARE THE SAME NUMBER, THE ENT 1
RELAY WILL NOT LATCH OR TIME OUT. IT WILL ENERGIZE BRIEFLY, AND THEN
DE-ENERGIZE.
ENTRANCE X LATCH TONE
The Entrance X latch tone refers to the touch tone numbers that allow the entrance to
automatically latch open when called in remote control mode. To change the number from the
default setting of 0 to another number, press "4" from the ENT 1 Control menu. Select the new
number (from 0 - 9) and press the “Enter” key. You will be returned to the Entry Control menu.
SELECTING A "0" DISABLES THE LATCH TONE FUNCTION. Selecting a number from 1 - 9 allows
that number to automatically latch open the door for that entrance.
ENTRANCE X AJAR TIME
Press "5" from the Entry Control menu to set the ajar time. The ajar time is the length of time an
entrance may be left ajar before energizing the optional alarm relay. This time is programmable from
1—99 seconds. Default is 0 (Off)
(CAT Shown. TEC is similar.)