TEC Series v 3.2X
Page 65
ACCESS LEVELS continued
AUTOMATIC UNLOCK AND RELOCK BY TIME ZONE
The following example shows how a business might keep two entrances open during peak
employee traffic, and secure those two entrances at all other times. Time Zone 1 is valid for one half
hour in the morning, Monday through Friday. Time Zone 2 is valid for one half hour in the afternoon,
Monday through Friday. Time Zone 0 is valid all the time, except Holidays.
Each Time Zone is assigned to a different Access Level. Both entrances are selected in the
Access Levels. The morning and the afternoon Access Levels are grouped together in Access Group 1.
By setting Entrance Group 1 to Access Group 1, the entrance will automatically unlock during
peak traffic, and relock at all other times. Employees whose PIN codes or cards are set to Access Level
0, can open the entrance at all other times. If employees try to use their PIN code while the entrances
are unlocked, the display on the TEC will show "OPEN".
ACCESS TIME
0
1
2
3
4
5
6
7
ENTRANCE
ACCESS
LEVEL
TIME
ZONE
1
2
3
4
0
1 1 X X
2 2 X X
AL1 (USES TIME ZONE 1 MORNING
HOURS M - F) , Entrances 1 & 2
AL2 (USES TIME ZONE 2 AFTERNOON
HOURS M - F), Entrances 1 & 2
Access Level Setting
Time Zone Setting
Start Time Stop Time Day of the Wk
Time
Zone
Hours
HH
Min.
MM
Hours
HH
Min.
MM
SU
MO
TU
WE
TR
FR
SA
Hol
0
1 07 45 08 15
X X X X X
2 16 45 17 15
X X X X X
SETUP AND PROGRAMMING