“MUSA Plus Eco
Electronic control for towel radiators
Rev. 02
Sept. 201
7
Selmo Electronic
Viia Pacinotti, 24 - 35030 Rubano (PD) Italy- Tel 049.8976761, Fax 049.8976085 - www.selmo.it
EN
Introduction
•Seven operational modes: Comfort, Night, Antifreeze, Fil-Pilote, Chrono, Timer-
2h, Stand-by.
"Comfort" mode: The thermostat keeps the room temperature at the value set by
the user.
"Night" mode: The electronic control keeps the room temperature to a level below
the configured “Comfort” value.
"Antifreeze' mode: The electronic control keeps the room temperature above 7°C.
"Fil-Pilote" mode: The operations of device are controlled through the signal
received from the "Fil-Pilote" system.
"Timer-2h" mode: The electronic control powers the heating element for a period
of 2 hours independently of the configured temperature. At the end of the 2 hours
time period, the device returns to previous operational mode. For safety reasons,
during the 2 hours time period the room temperature is automatically controlled in
order not to exceed 32°C.
"Chrono" mode: The electronic control operates according to a daily/weekly
program. The program is user defined.
-In "Stand-by": The electric resistance is not powered and all lights are turned off,
however the device is still operative.
Further features:
•Large display showing the configured temperature, time, program and current
operational mode.
•The user according to his needs can configure the daily/weekly program.
•The “Open Window Detection” function enables detecting of an open window by
sensing a sudden decrease of the temperature in the room. In such a case, the
device deactivates the heating element for a maximum of 30 minutes or until an
increase of the room temperature reveals that the window has been closed.