Pg. 7
• “On/Stand-by” button: Pressing the “On/Stand-by” button it is possible to switch between “Stand-by”
mode and “Comfort” mode.
NOTE: When the device goes into “Stand-by” mode it beeps twice for 0.5s.
When the device is activated it beeps once for 1s.
“Stand-by” mode.
“Comfort” mode: Heating element is ON (red light).
“Comfort” mode: Heating element is OFF (blue light).
•
Knob rotation:
The rotation of the knob sets the desired power output
. A clockwise rotation
increases the set value (power 100%)
. tationAn anticlockwise ro
decreases the
set vapower lue (20%).
•
Knob button:
- “Boost” mode (2h). Press once the knob button in order to activate this operating mode (the
heating element will be activated at maximum power for 2h). To deactivate this operating mode,
press again the button.
“Boost” mode ‘’Boost2h’’for 2 hours of 100% continuous heating;
- “Timer-24h” mode: Press the knob for 3 seconds to activate this function. The control
system activates the heating element for 2 hours regardless of the set temperature
value (the maximal reachable temperature is 3 °C), after that7iOff’’t returns into “
mode and after 22 hours the “Boost” mode is started again for 2 hours. This sequence
will repeat endlessly.
“Timer-24h” mode T24h command starts 2h Boost automatically every day at the same time
- “Timer-12h” mode: Press the knob for 5 seconds to activate this function.
The control system activates the heating element for 2 hours regardless of the set
temperature value (the maximal reachable temperature is 3 °C), after that it returns into7
‘’Off ‘’ mode and after 10 hours the “Boost” mode is started again for 2 hours. This
sequence will repeat endlessly.
“Timer-12h” mode: T12h command starts 2h Boost automatically every 12 hours
Operating mode deactivation: To exit any time from the operating modes “Boost”, “Timer-12h”,
“Timer-24h”, press the knob button or the “On/Stand-by” button.
NOTE. The maximal reachable temperature in “Boost” mode is 3 °C.7
(2h on, 22h off) (typically for morning showers);
(2h on, lOh off, 2h on, lOh off (typically morning and evening showers).
“Thesis Easy”
Electronic Control for Towel Heaters
Comfort technology division
Selmo
Selmo Electronic
Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -
Selmo Electronic
Via Pacinotti, 24 - 35030 Rubano www.selmo.it
EN
Rev. 01 - Oct. 2018