EasyManuals Logo

Selmo Thesis Plus User Manual

Selmo Thesis Plus
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Comfort technology divisio
n
“THESIS PLUS”
E
lectronic control for towel radiator
s
Selmo Electronic
Via Pacinotti, 24 - 35030 Rubano (PD) Italy- Tel +39.049.8976761, Fax +39.049.8976085 - www.selmo.it
E
N
Rev.13 November 2015
• “On/Stand-by” button: Pressing the “On/Stand-by” button it is possible to switch between “Stand-by”
mode and “Comfort” mode.
NOTE: When the device goes into “Stand-by” mode it beeps twice for 0.5s.
When the device is activated it beeps once for 1s.
“Stand-by” mode.
“Comfort” mode: Heating element is ON (red light).
“Comfort” mode: Heating element is OFF (blue light).
Knob rotation:
The rotation of the knob sets the desired room temperature. A clockwise rotation
increases the set temperature value (max 32°C). An anticlockwise rotation decreases the
set temperature value (min 7°C).
Knob button:
- “Boost” mode (2h). Press once the knob button in order to activate this operating mode (the
heating element will be activated at maximum power for 2h). To deactivate this operating mode,
press again the button.
“Boost” mode: “Boost” for 2h (blinking red light).
- “Timer-24h” mode: Press the knob for 3 seconds to activate this function. The control
system activates the heating element for 2 hours regardless of the set temperature
value (the maximal reachable temperature is 32°C), after that it returns into “Comfort”
mode and after 22 hours the “Boost” mode is started again for 2 hours. This sequence
will repeat endlessly. During the first cycle the duration of the “Comfort” mode is of 21
hours.
“Timer-24h” mode: - “Boost” for 2h (blinking green light).
- “Comfort” for 22h (permanent green light).
- “Timer-12h” mode: Press the knob for 5 seconds to activate this function.
The control system activates the heating element for 2 hours regardless of the set
temperature value (the maximal reachable temperature is 32°C), after that it returns into
“Comfort” mode and after 10 hours the “Boost” mode is started again for 2 hours. This
sequence will repeat endlessly. During the first cycle the duration of the “Comfort” mode
is of 9 hours.
“Timer-12h” mode: - “Boost” for 2h (blinking amber light).
- “Comfort” for 10h (permanent amber light).
Operating mode deactivation: To exit any time from the operating modes “Boost”, “Timer-12h”,
“Timer-24h”, press the knob button or the “On/Stand-by” button.
NOTE. The maximal reachable temperature in “Boost” mode is of 32°C.