How to troubleshoot Senco PC1010 motor that will not run?
- LLeslie WilliamsAug 16, 2025
If the Senco Air Compressor motor won't run or restart, first, ensure the power cord is plugged into a grounded outlet. Then, check that the motor/pressure switch is in the ON (1) position. If it still doesn't work, the motor thermal overload switch may have tripped; turn the compressor off, let the motor cool, and check the motor circuit breaker. Also, verify the fuse and replace or reset the circuit breaker, ensuring the fuse amperage is correct and there are no low voltage conditions. Avoid using the extension cord of the wrong gauge wire or length. The motor will start automatically when air tank pressure drops below the motor/pressure switch’s cut-in pressure. If the pressure release valve hasn't unloaded pump head pressure, bleed the line by moving the switch to the OFF (0) position.