Fireplace stove SENKO SP 22
8. PROBLEMS / CAUSES / SOLUTIONS
PROBLEM POSSIBLE CAUSE SOLUTION
The glass on the
combustion chamber
door is blackened
and/or the combustion
chamber is smoky
(black soot)
too small
underpressure (less
than 10 Pa)
bad air regulation
too much fuel in the
combustion chamber
fuel with too much
moisture
inappropriate fuel
too high temperature
in the combustion
chamber
� check the chimney and the
connection of chimney and
the stove
� study chapters 4.2. and
4.3. � study chapters 5.1.
� reduce the amount of fuel
� use fuel with less than
17% relative humidity
� use fuel according to
chapter 1.1.
� reduce the amount of fuel
and primary air and adjust
the chimney vacuum
according to
chapter 5.1.
Insucient negative
pressure in the
chimney; black smoke
comes out of the
chimney
the chimney is sooty
replace stove stoveis
smoky
chimney partially
clogged or sooty
fuel with too much
moisture
cast grate in the
combustion chamber facing
the wrong way
combustion chamber open
Inappropriate
underpressure
bad air regulation
� clean the chimney
� clean the replace stove
� unclog and clean the
chimney
� use fuel according to
chapter 1.1.
� place the grid according
to chapter 5.2.
� close the door
� adjust the chimney
underpressure according to
chapter 4.2.
� adjust the primary and
secondary air according to
chapter 5.1.
Smoking from the
replace stove
sooty replace stove
sooty chimney
fuel with too much
moisture
low-calorie fuel
insucient amount of
fresh air in the room
too low temperature in
the combustion chamber
chimney lower than 4.5 m
a chimney with a smaller
diameter than prescribed
� clean the replace stove
according to chapter 6.
� clean the chimney according
to chapter 6.
� use fuel according to
chapter 1.1.
� study chapter 4.4.
� increase the temperature in
the combustion chamber by
adding more fuel
� adjust the chimney according
to chapter 4.2. and 4.3.