Fireplace stove SENKO SP 24
10.TECHNICAL DATA
SENKO replace stove SP Values
Nominal heat output, kW
5,2
Space, kW
5,2
Width, mm
700
Depth, mm
350
Height, mm
825
Weight, kg
70
Opening of combustion chamber (wxh), mm
270×212
Combustion chamber (wxd), mm
280×230
Volume of combustion chamber, dm
3
13,76
Ash box, L
2
Chimney connection, mm
150
Flue gas temperature, °C
238
Required chimney underpressure, Pa
12
CO in ue gases at 13% O2, %
946
Eciency, %
75,2
Regulation
Primary air manual
Secondary air -
Made in accordance with EN standards
EN 16 510-1 2019
EN 16 510-2-1:2023
EN 13 240/A2:2005
- technical data refer to the use of wood and wood briquettes as fuel
- technical data are indicative and subject to change. The manufacturer reserves the right
to change all technical data for the purpose of improving its products