Sensopart FT 50 RLA-70 - User Manual

Default Icon
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
安装使用说明书
FT 50 RLA
70-L8
70-S1L8
70-S1L8-X02
100-L8
100-S1L8
220-L8
220-S1L8
220-S1L8-X01
测距传感器
Distance sensor

Table of Contents

Questions and Answers

  • E
    edwardspaulAug 11, 2025
    What to do if the Sensopart FT 50 RLA-70 Accessories sensor is not found by the software after connection?
    • D
      Daniel PowersAug 11, 2025
      If the Sensopart Accessories sensor is not found by the software after connection, it might be programmed as a master or slave. Reset the sensor to factory settings via the control panel.
  • R
    Robert LevineAug 19, 2025
    Why does the Sensopart Accessories sensor no longer react to the program after activating fast measurement value?
    • T
      Terry KellyAug 19, 2025
      If the Sensopart Accessories sensor no longer reacts to the program after activating fast measurement value, it may be because PIN 3 (Q1) = +UB or Q1 was set to high via software. You can set Q1 back to low to make settings possible again. Alternatively, disconnect the power supply and restart the sensor to make it operational again.
  • K
    Katie KaufmanAug 27, 2025
    What to do if the Sensopart FT 50 RLA-70 sensor does not switch to set-up mode?
    • C
      Candice Sanchez MDAug 27, 2025
      If the Sensopart Accessories sensor does not switch to set-up mode via the control panel, it might be simultaneously operated via the interface. Try disconnecting the serial interface.
  • A
    Amanda WareSep 3, 2025
    Why is the master-slave mode not functioning on my Sensopart Accessories?
    • R
      Robert HodgeSep 3, 2025
      If the master-slave mode for Sensopart Accessories does not function and LED C is only lit on one sensor, it could be due to one sensor not being in the correct mode or not having function no. 27. Reprogram the sensor whose LED is not lit, or use the sensor that does not have function 27 as the master.

Sensopart FT 50 RLA-70 Specifications

General IconGeneral
ShapeRound
Diameter50 mm
ModelFT 50 RLA-70
Operating voltage10-30 V DC
Output typePNP
Switching distance70 mm
Housing materialPlastic
Protection classIP67