Measuring Chamber 4
This section describes how to remove the measuring chamber and how to
disassemble the measuring chamber when required to do so.
Tools Required
2.5, 3, and 6mm hex head ball end drivers (6mm not needed for the R2)
Sensus seal screw tool—for bonnet removal
Open end/box wrenches as determined by size and type of OMNI meter
7/16”x1/2” open end/box wrench
9/16” x 5/8” open end/box wrench
3/4” x 11/16” open end/box wrench
15/16” open end/ box wrench
Assembly grease
CAUTION: If the meter is under pressure, pressure must be turned off
and relieved before chamber bolts are loosened or removed!