DAL 1965
Pag. 3/6
STIRRUP WITH UNCLAMPING
THREADY PINS TO HOUSE THE MOTOR
COVER
CONNECTING ROD
GEARED MOTOR
CAPACITOR
FOUNDATION BOX
CLOSING / OPENING
STOPBLOCKS
MAX 95° MAX 95°
1- Check for best motor positioning and set up the opening angle
2- Get n.4 stop blocks and place them right where you want mouvement is to be stopped
The installation of mechanical stop-blocks for opening and closing phase is necessary to
guarantee system security and therefore it is compulsory to install them, before installing the
control panel.
PILLAR PILLAR
MAX 110° MAX 110°
PILLAR PILLAR
!
IMPORTANT:
GREASE THE BOLT
BEFORE FITTING THE
LEVER GROUP
!
IMPORTANT:
USE THE PROPER GREASER TO
LUBRICATE PERIODICALLY THE
BOLT -EVERY 6 MONTHS
!
MT/80/2 I E