INSTALLATION & OPERATION MANUAL
GAS RESTAURANT RANGES
Models: SGR-4, SGR-2-12G, SGR-24G,SGR-6,
SGR-2-24G, SGR-4-12G, SGR-10, SGR-6-24G,
SGR-4-36G

Questions and Answers

  • H
    henrycodyAug 4, 2025
    What to do if the pilot light keeps going out on my SERV-WARE Ranges?
    • K
      Krystal CameronAug 5, 2025
      If the pilot light on your SERV-WARE Ranges is constantly going out, there are several potential causes. First, the pilot flame might be too low, so try adjusting it. There could also be a restriction in the pilot orifice; clear any obstructions. Other possible issues include problems with the shutoff valve (check and repair it), fluing problems (inspect and fix them), low pressure (investigate and correct it), improper gas line sizing (ensure it's properly sized), the burner box cover not properly installed (install it correctly), or the oven cavity requiring resealing (reseal the oven cavity).
  • L
    laurie66Aug 9, 2025
    Why is there too much bottom heat in my SERV-WARE Ranges oven?
    • J
      Jean DaltonAug 9, 2025
      Excessive bottom heat in your SERV-WARE Ranges oven can stem from several factors. It could be due to insufficient ventilation, so check and improve the ventilation around the oven. Improper fluing can also cause this issue; ensure proper fluing is installed. Other potential causes include an improper thermostat bypass setting (adjust it), a thermostat out of calibration (calibrate it), or fluctuating gas pressure (investigate and stabilize it).
  • C
    cmullenAug 12, 2025
    Why is my SERV-WARE Ranges oven baking unevenly from side to side?
    • J
      Jesse RussellAug 12, 2025
      Uneven baking from side to side in your SERV-WARE Ranges oven can be due to a few reasons. The oven might not be level, so level it side to side. The oven burner, bottom, or baffles could be improperly installed; ensure they are correctly installed. Also, warped pans can cause uneven baking; use non-warped pans.
  • J
    johnsonkarenAug 17, 2025
    What to do if my SERV-WARE Ranges oven is baking unevenly from front to back?
    • B
      Benjamin PearsonAug 17, 2025
      If your SERV-WARE Ranges oven is baking unevenly from front to back, consider these potential causes: an overactive flue (check and adjust its activity), the oven not being level from front to back (level it, checking casters and legs), or the door not closing properly (ensure it closes correctly).
  • M
    Matthew ThomasAug 21, 2025
    How to fix poor ignition in SERV-WARE Ranges?
    • R
      regina23Aug 21, 2025
      Poor ignition in your SERV-WARE Ranges can be caused by several factors. There might be insufficient input; check the input supply. Poor air-gas adjustment could also be the culprit; adjust the air-gas mixture. Additionally, check for a restriction in the pilot orifice and clear it, or a restriction in the main burner ignition port and remove it.
  • P
    phayesAug 26, 2025
    What causes dried out products in SERV-WARE Ranges, and how to prevent it?
    • A
      Angel StanleyAug 26, 2025
      If your products are drying out in your SERV-WARE Ranges, it could be due to a temperature that is too low, leading to overcooking; increase the baking temperature. Alternatively, the baking time might be too long, so reduce it. Also, ensure that the thermostat is properly calibrated.
  • K
    Kimberly WalshAug 30, 2025
    Why am I experiencing improper burner combustion, excessive valve handle temperatures, and sticking top burner valves on my SERV-WARE Ranges?
    • B
      brianmooreAug 30, 2025
      These issues with your SERV-WARE Ranges can arise from improper ventilation, so check the ventilation. A poor door fit can also contribute, so fix the door fit. Ensure the oven door isn't left open. Finally, using excessively large pans or pots improperly can cause these problems, so use appropriately sized pans or pots.

Summary

General Safety Warnings

Installation & Maintenance Risks

Improper installation, adjustment, or maintenance can cause severe damage, injury, or death.

Key Safety Directives

Qualified Personnel for Installation

Manual is for qualified personnel; initial start-up and adjustments must be performed by them.

Gas Leak Emergency Response

Procedure for responding to detected gas odor: shut down units and contact gas company.

Installation, Operation, and Care Overview

Installation Codes and Clearances

Leveling and Gas Connections

Gas Supply Connection Procedure

Connect gas supply using 3/4" pipe; ensure a gas shutoff valve is installed in the line.

Gas Pressure Regulator Installation

Install field-provided regulator, ensuring it matches the rating plate and is oriented correctly.

Gas System Checks and Flue Connections

Regulator Mounting and Leak Testing

Mount regulator horizontally, use leak limiters, and check all joints with soap and water for leaks.

Gas Supply Pressure Testing

Test gas supply pressure; isolate range if it exceeds 1/2 psig or close shutoff valve if 1/2 psig or less.

Appliance Operation and Controls

Hot Surface Safety Warning

Exercise caution as the range and its parts are hot during operation, cleaning, or servicing.

Pilot Lighting Procedures

Oven Pilot Lighting and Shutdown

Oven Features and Maintenance

Maintenance Safety Precautions

Be extremely careful when performing maintenance, as the range and parts are hot.

Troubleshooting Common Issues

Oven Performance Problems

Lists common oven issues like temperature, bottom/top heat, and uneven baking with potential causes.

Top Burner Operation Problems

Lists common top burner issues like combustion and ignition problems with potential causes.

Gas Conversion Kit Instructions

Conversion Kit Installation Warning

Gas conversion must be done by a certified/licensed technician to prevent fire, explosion, or CO risks.

Gas Conversion Procedure Steps

Final Gas Conversion Steps

Convertible Regulator Setup for L.P.

Instructions to reverse the plastic insert on the convertible regulator to set it for L.P. gas use.

SERV-WARE SGR-2-24G Specifications

General IconGeneral
Burners2
Power TypeGas
Burner TypeOpen
IgnitionManual
MaterialStainless Steel
Width24 inches
TypeRange
Gas TypeNatural Gas
Warranty1 year