CDHD2
28 Operator Panel (HMI)
Save Parameters
Code
C0006
Command
Save Parameters
VarCom
SAVE
Sequence
Select: C0006
Press: Shift
Display: done
(or an error code)
Encoder Multi-Turn Reset
Code
C0007
Command
Encoder Multi-turn Reset
VarCom
MTTURNRESET
Sequence
Select: C0007
Press: Shift.
Display: done
(or an error code)
Restore Factory Settings
Code
C0008
Command
Restore Factory Settings
VarCom
FACTORYRESTORE
Sequence
Make sure drive is Disabled.
Select: C0008
Display: frstr
Press: Shift
Display: Flashing 0. in digit 1
Press: Up (>1) for digits 1 to 4
Display: 0 1 1 1 1.
Press: Long Shift
Display: done (momentarily), then flashes, and stops.