CDHD2
Operator Panel (HMI) 29
Analog Input 1 Zero
Code
C0009
Command
Analog Input 1 Zero Command
VarCom
ANIN1ZERO
Sequence
Make sure drive is Disabled.
Select: C0008
Press: Shift
Display: Flashing 0. in digit 1
Press: Long Shift
Display: done
(or an error code)
Move Absolute - Distance
Code
C0010
Command
Move Absolute - distance
VarCom
MOVEABS {distance} {velocity}
Sets the distance argument. Command uses velocity value set by JOGSPD1.
Sequence
Make sure drive is Enabled.
Select: C0010
Display: absnn
Press: Long Shift
Display: Flashing 0. in digit 1
Press: (for example) Set a value of 15 (revolutions)
Press: Long Shift
(motor rotates)
Display: abSnn (during motor movement)
Display: done
(or an error code)