The 231 offers 8 field selectable pressure ranges changed via a slide switch, reducing risk of installing the wrong range unit.
Optional 3 or 5 valve manifold saves money on installation and maintenance, eliminating the risk of internal leaks.
NEMA 4 housing with optional LCD display and hinged cover is suitable for harsh environments.
Details on excitation, output, and circuit consumption for voltage configurations of the Model 231.
Details on circuit, output, external load, and supply voltage for current configurations of the Model 231.
Information on the case material, pressure fittings, electrical connection, size, weight, and sensor volume.
Specifies operating and storage temperature ranges for the Model 231 transducer.
Provides dimensions and configuration details for the 3-valve manifold assembly.
Provides dimensions and configuration details for the 5-valve manifold assembly.
Details on model codes, range specifications, pressure connections, and display options for ordering.
Illustrates the typical installation setup for the Model 231 with high and low pressure sensors.
Guide to selecting the correct range code based on highest system line pressure and differential pressure.
The 231 offers 8 field selectable pressure ranges changed via a slide switch, reducing risk of installing the wrong range unit.
Optional 3 or 5 valve manifold saves money on installation and maintenance, eliminating the risk of internal leaks.
NEMA 4 housing with optional LCD display and hinged cover is suitable for harsh environments.
Details on excitation, output, and circuit consumption for voltage configurations of the Model 231.
Details on circuit, output, external load, and supply voltage for current configurations of the Model 231.
Information on the case material, pressure fittings, electrical connection, size, weight, and sensor volume.
Specifies operating and storage temperature ranges for the Model 231 transducer.
Provides dimensions and configuration details for the 3-valve manifold assembly.
Provides dimensions and configuration details for the 5-valve manifold assembly.
Details on model codes, range specifications, pressure connections, and display options for ordering.
Illustrates the typical installation setup for the Model 231 with high and low pressure sensors.
Guide to selecting the correct range code based on highest system line pressure and differential pressure.
| Output | 4-20 mA, 0-5 VDC, 0-10 VDC |
|---|---|
| Operating Temperature | -40 to 85°C |
| Power Supply | 12 to 30 VDC |
| Electrical Connection | Cable |
| Process Connection | 1/4" NPT |
| Accuracy | +/-0.25% FS |