EasyManuals Logo

Setra Systems Quick Count User Manual

Default Icon
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
20
Setra Super Count
TM
Operator's Manual
COUNTING WITH THE DATABASE
To perform the following procedure the automatic APW/tare retrieval system must be enabled. To
enable the system refer to DATABASE SETUP.
To count parts using a stored APW follow the steps below:
1. Press the reset key. This will zero the scale and clear the ID, APW and tare registers.
2. Enter the ID, up to ten characters.
3. Press the id key.
4. The scale will automatically enter the counting mode if a matching ID is found. Parts may now
be placed on the pan to be counted. Note; the APW and tare will reflect the values stored
under the recalled ID.
If no matching ID is found, the scale will accept the entry as a new ID and will not enter the counting
mode.
PRINTING IDs & APW/TARE VALUES FROM THE DATABASE
This setup allows the stored IDs and their associated APW and tare values to be transmitted to a
printer, computer or another scale as backup.
To transmit the stored IDs and their associated APW and tare values use the following procedure:
1. Enter — 17776 and press the setup/cal key.
2. The scale will display “ID SC.”
3. To transmit the ID, APW and tare values to another scale or computer press the setup/cal key.
To transmit the data to a printer press the clear key.
4. The scale will display “ID PR.” To print the data to a serial printer press setup/cal. To exit this
setup press the clear key.
NOTE: A backup copy of the stored IDs may be transmitted to a computer and stored on disk.
Selecting “ID SC” will instruct the scale to also send the control codes which are required
when the data is read back into the scale. When the data is later transmitted back to the scale
from a computer, each record (1 record = 1 ID and associated APW and tare value) must be
followed by a 3 second delay. The Save and Restore program that comes with the Auto Count
200 can be used to backup the scale database.
UPDATING AN ID AND APW/TARE VALUES IN THE DATABASE
To perform the following procedure the database must be enabled and APW and tare values must not
be protected. (To enable the system refer to DATABASE SETUP.) (See PROTECTING THE APW/TARE
VALUES to select a specific form of ID protection.)
To update an ID and its associated APW and tare values follow the steps below:
1. Enter the ID and press the id key. The scale will enter the counting mode.

Other manuals for Setra Systems Quick Count

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Setra Systems Quick Count and is the answer not in the manual?

Setra Systems Quick Count Specifications

General IconGeneral
BrandSetra Systems
ModelQuick Count
CategoryScales
LanguageEnglish

Related product manuals