8.1 Oil change.
1 Keep the engine running during 5 to 10 minutes for the oil to reach some
temperature and reduce its viscosity (more liquid). This way it will be easier to
extract it completely.
2 Open the maintenance access cover by releasing the closing screw.
3 Open the evacuation cover so the oil may pour through this hole out of the
equipment and place a tray under the equipment to collect the oil.
4 Unscrew the oil draining screw by turning counter clockwise and allow all the
spent oil to pour out.
5 Once all of the oil has been extracted, place the evacuation cover again, as
well as the drain plug. Clean any oil spills.
MAINTENANCE CAP
EVACUATION COVER
OIL DRAINING SCREW