ADJUSTMENT PRECAUTIONS
This model’s setting are adjusted in two different ways: though the I
2
C bus control and in the
conventional analog manner. The adjustments via the I
2
C bus control include preset-only items
and variable data.
1. Setting the service mode by the microprocessor.
1 Make a short-circuit JA122 and JA124 for a second and release to switch to the service
mode position and the microprocessor is in input mode. (Adjustment through the I
2
C bus
control). (Use JWS Key to set as well).
2 Press the CH DOWN / UP key on the remote controller to get ready to select the mode
one by one.
3 Press the CH DOWN / UP key on the remote controller to select the modes reversibly
one by one.
4 Using the VOLUME UP/ DOWN key on the remote controller, the data can be modified.
5 Make a ashort circuit JA122 and JA124 for a second and release to switch to the normal
mode (OFF) position and the microprocessor is in out of the service mode.
2. Factory Presetting.
1 Make a short-circuit JA122 and JA124 for a second and release to switch to the service
mode position and turn on the main power switch. Initial values are automatically preset,
only when a new EEPROM is used (Judge with the first 4 bytes).
2 The initial data are preset as listed in pages 5-7.
3 Make sure the data need modify or not (Initial data).
Note: Once the chassis has been assembly together and ready to be POWER ON for the
FIRST TIME, make sure to short-circuit JA122 and JA124 to switch to the service
mode position first and then turn on the main power switch. (See 2-1 above).
Precaution: If haven’t done this initiation, it may possibly generate excessive Beam
current.
3. For reference please check with memory map
(UA1 Series type RH-IX3410CE Attachment)
AGC &
GEOMETRIC
MODE
AGC TAKE OVER POINT (AGC)
VERTICAL SLOPE (V-LIN)
VERTICAL AMP (V-AMP)
VERTICAL SHIFT (V-CENT)
HORIZONTAL SHIFT (H-CENT)
HORIZONTAL PARALLELOGRAM (EW//)
EAST-WEST PARABPLA/WIDT (PARA)
HORIZONTAL BOW (HB)
S-CORRECTION (S-COR)
WHITE POINT
ADJ.
MODE
W.P. RED STD. W.T. (DRI-RS)
W.P. GREEN STD. W.T.(DRI-GS)
W.P.BLUE STD. W.P. (DRI-BS)
W.P. RED COOL W.P.(DRI-RC)
W.P. GREEN COOL W.P.(DRI-GC)
W.P. BLUE COOL W.P. (DRI-BC)
W.P. RED WARM W.P.(DRI-RW)
W.P. GREEN WARM W.P.(DRI-GW)
W.P. BLUE WARM W.P.(DRI-BW)
SUB
ADJ.
MODE
MAX VOLUME (SUB-VOL)
SUB CONTRAST (SUB-CON)
SUB COLOUR (SUB-COL)
SUB BRIGHTNESS (SUB-BRI)
SUB TINT (SUB-TINT)
SUB SHARPNESS (SUB-SHP)
MAX HOTEL VOLUME (HTL-VOL)
HOTEL PROGRAM NO(HTL-PRG)
BLUE BACK CONTRAST (BB-CON)
OSD GRB REFERENCE (RGB)
BLACK LEVEL OFFSET R(CUT-R)
BLACK LEVEL OFFSET G(CUT-G)
CATHODE DRIVE LEVEL(CDL)
FORWARD : CH DOWN KEY
REVERSE : CH UP KEY
* ( ) means OSD display.
FORWARD : CH DOWN KEY
REVERSE : CH UP KEY
AGC &
GEOMETRIC
MODE
WHITE POINT
ADJ.
MODE
SUB
ADJ.
MODE
Y-DELAY
ADJ.
MODE
IC
OPTION
MODE
OFFSET
ADJ.
MODE
MISC.
OPTION
MODE
STEREO
ADJ.
MODE
Ë
SERVICE MODE
(1)In the Service Mode, Key is used to select the mode in the following order.