EasyManua.ls Logo

Sharp 20U200 - CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT; CRT CUTOFF (I2 C BUS CONTROL); SUB-BRIGHTNESS ADJUSMENT (I2 C BUS CONTROL); WHITE BALANCE SERVICE MODE ADJ. (I2 C BUS CONTROL)

Sharp 20U200
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
20U200, 20U250
51U200, 51U250
51U500, 51U550
9-1 9-2
1. Call "SUB-BRI" in service mode. (Receive
Crosshatch pattern with 5 black level windows)
2. Adjust the "SUB BRIGHT" bus data in order
that the line 1, 2 and 3 have the same darkness
wherelse line 4 is slightly brighter than line 1,
2 and 3 and finally line 5 will be the brighter
than line 4.
1. Switch TV to VIDEO mode, BLUE BACK OFF
with NO VIDEO signal.
2. Press R/C to set Picture Normal condition.
3. Connect the oscilloscope to Red OUT from
IC801. (TP851)
Range : 1 V/Div (DC)
Sweep : 5 msec/Div
4. Adjust SCREEN VR, so that the tip of signal
reach 3.0 ±0.1 Vdc.
CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT
NO. Adjustment part Adjusting procedure and conditions Waveform and others
1
2 SUB-
BRIGHTNESS
ADJUSMENT
(I
2
C BUS
CONTROL)
1, 2 and 3 are in same black level.
CRT CUTOFF
ADJUSTMENT
(I
2
C BUS
CONTROL)
Fig. 6
3 WHITE
BALANCE
SERVICE
MODE ADJ.
(I
2
C BUS
CONTROL)
1. Receive the "Monoscope Pattern with BURST"
signal.
2. Press R/C to set Picture NORMAL condition.
3. Connect the DC miliammeter between TP602
(-) and TP603 (+).
4. Check Beam current should be around 1,100 µA.
5. Set it to service mode and adjust the " DRI-
GS" & "DRI-BS" data to have a colour
temperature of 12,300°K. (Note.)
6. Receive "White" pattern, with BURST Signal, and
set Brightness Y by generator, to** 10 cd/m
2
(Minolta CA-100) by reducing Luminate Y signal.
7. Adjust "CUT-R" & "CUT-G" to get 12,300°K. Then
go back normal mode (High Bright)** to check
colour temperature. If out of range, back to 1.
Note: This adjustment must be done after
warming up the unit for 30 minutes
or longer with a beam current over
700µA).
* Adjust DRI-GC/GW, DRI-BC/BW as following
data after finishing DRI-GS and DRI-BS.
DRI-GC/GW DATA="DRI-GS" -7 DATA
DRI-BC=DRI-BS
DRI-BW DATA="DRI-BS" -7 DATA
** Low=10 cd/m
2
: High=120 cd/m
2
Refer to Page 7.
* 12,300°K X : 0.272
Y : 0.275
(MINOLTA COLOUR ANALYZER
CA-100)
(Note): Above Data can be UP/
DOWN by Volume key.
4 Maximum
beam check
1. Receive the "Monoscope Pattern" signal.
2. Press R/C to set Picture NORMAL condition.
3. Connect the DC miliammeter between TP603
(+) and TP602 ().
(Full Scale: 3 mA Range)
4. Beam current must be within 1,100 ±100 µA.
1 V
3.0Vdc
0
1 2 3 4 5
Fig. 7
HORIZONTAL, VERTICAL, DEFLECTION LOOP AND FOCUS ADJUSTMENT
NO. Adjustment part Adjusting procedure and conditions Waveform and others
1
2
3
4
5
6
V-SLOPE
(I
2
C BUS
CONTROL)
V-SHIFT
(I
2
C BUS
CONTROL
V-AMP
(I
2
C BUS
CONTROL)
S-CORREC-
TION (I
2
C
BUS CON-
TROL)
H-SHIFT (50)
(H - CENTER)
(I
2
C BUS
CONTROL)
FOCUS
1. Receive "PAL 50Hz Monoscope Pattern"
Signal.
2. Call the "V-LIN" mode.
3. Increase or decrease "V-LIN" by Volume key till
the horizontal line in the center of monoscope is
just at the position where the blanking starts.
1. Call the "V-CENT" mode.
2. Increase or decrease "V-CENT" by Volume key
till the picture is centered.
1. Call the "V-AMP" mode.
2. Increase or decrease "V- AMP" by Volume key
to set overscan of 8.5% typical.
Adjustment Spec 8.5% range +1% -0%.
FIXED DATA, NO NEED TO ADJUST.
1. Call the "H-CENT" mode.
2. Increase or decrease "H-CENT" by Volume key
to center the picture horizontal.
1. Receive the "Monoscope Pattern" signal.
2. Press R/C to set Picture NORMAL condition.
3. Adjust the focus control to get the best
focusing.
PAL CHROMA ADJUSTMENT
NO. Adjustment part Adjusting procedure and conditions Waveform and others
1
SUB COLOUR
(I
2
C BUS
CONTROL)
1. Receive the "PAL Colour Bar" signal.
2. Press R/C to set Picture Normal condition.
3. Connect the oscilloscope to Red cathode
(Between C881 and R885).
» Range : 20 V/div. (AC) (Using 10:1 probe)
» Sweep time : 10 µsec/div.
4. Using the R/C call "SUB COL" in SERVICE
mode. Adjust SUB COLOUR bus data, so that
the 75% White & Red portions of PAL Colour
Bar be at the same level shown as Fig. 8.
5. Clear the SERVICE mode.
Cy
G
B
W
Y 100%W
75%
Mg R
Fig. 8

Related product manuals