21V-FW100S
5 – 8
MODEL NAME
ADJUSTMENT
ITEM
ADJUSTMENT
POSITION
CONTROL
PRE-ADJUST
REQUIREMENT
CONTENT
INPUT
CONDITION
OUTPUT
(AT SELF ADJUSTMENT MODE)
1) GO INTO SERVICE MODE,BY SELECTING THE SERVICE DATA V13
2) PRESS THE R/C FOR AUTO PIF-VCO KEY, OSD APPEAR "OK" AT SCREEN
3) IF APPEAR "NG" PLS REPEAT STEP 2
(AT MANUAL ADJUSTMENT MODE)
ADJUST
1) GO INTO SERVICE MODE, BY SELECTING THE SERVICE DATA V13
PROCEDURE 2) ADJUST THE DATA UP/DOWN UNTIL IC801 PIN 9 VOLTAGE BECOME AS SPECIFIED BELOW
HISTORY
OF REVISION
SYMBOL
REVISED CONTENT .
CONFIRMATION ON CRT DISPLAY(AUTO), IC801 PIN 9 VOLTAGE ( MANUAL).
[CHECKING SPEC]
2.5 ± 0.5 V DC (CHECKING SPEC : 2.50 ± 1.5 V)
I2C CONTROL
OPTION SET UP, BUS SET UP
NO SIGNAL (RAST ER) CONDITION
AC 220
21V-FW100S
PIF-VCO
V13
STEP RANGE
0-63