5 – 7
ADJUSTMENT
ITEM
ADJUSTMENT
POSITION
CONTROL
PRE-ADJUST
REQUIREMENT
CONTENT
INPUT
CONDITION
OUTPUT
ADJUSTMENT
PROCEDURE
SYMBOL
HISTORY
OF REVISION
REVISED CONTENT .
IC 801 PIN 15
(MANUAL ADJ)
1) GO TO SERVICE MODE,
2) GO TO SERVICE DATA
V24
, ADJ UNTIL FREQ AS BELOW
(SELF ADJ)
1) GO TO SERVICE MODE, BY SELECTING THE SERVICE DATA V24
2) PRESS THE R/C TO OPERATE AUTO H-VCO, OSD APPEAR "OK" AT SCREEN
3) IF APPEAR "NG" PLS REPEAT STEP 2
[CHECKING SPEC]
FREQ = 15.735 ± .02 KHz
I2C CONTROL
OPTION SET UP, BUS SET UP
NO SIGNAL (RASTER) CONDITION
AC 220
MODEL NAME
H-VCO
V24
STEP RANGE
0-7
21V-FW100S