2T-C45AE1X
5 – 6
6. WRITING PANEL SIZE
i. Enter the adjustment process mode [ PAGE 2/13 (INIT) ]
ii. Point the cursor to [PANEL SETTING]
iii. Select Panel Size and press [enter] key
02/11 [INIT]
FACTORY INIT General
PANEL SETTING PANEL_45_INNOLUX
PUBLIC MODE OFF
OPERATION ACUTIME xxxxH xxM
RESET OFF
7. POWER CONSUMPTION
Power Consumption Measurement Method
① Aging time : minimum 30 minutes
② Signal : Color Bar
③ Audio frequency : 400 Hz
④ AV Mode : Dynamic
⑤ Picture Setting : Backlight/ Brightness/ Contrast : MAX;
⑥ Audio Output (400 Hz) : 1/8 of Maximum Audio Output (10W + 10W) ;
VOL = 19
⑦ AC Input: 99VAC ~ 264VAC 50Hz
⑧ Wake UP LAN : Off
Model
2T-C45AE1X
Power Consumption Specification
(IEC600657)
Standard Value Limit Value
Power Consumption 82 W +10%
Power Consumption at Stand-by
Operating
0.45 W 0.3W ~ 0.6W
8. CHECKER PROCESS
i. Function Check : Main PWB inspection/functional check
ii. K-MODE Color Indication
-The default condition for K-Mode is Magenta colour.
-BecauseofthismodeldonʼthaveHDcomponent adjusment, Checker need to
be set to send the command(RSWR0201) to change the colour of K-Mode
from Magenta to Yellow.