AR-M350 SIMULATIONS 10-19
<List of set values>
<List of set values>
<List of set values>
<List of set values>
<List of set values>
Main code 14
Purpose Cancel (in case of a trouble)
Function (Content) Used to cancel the self diag U1/LCC/US/PF
troubles.
Section
Item Trouble
Operation/Procedure Select with 10 digit key pad
1 After canceling a trouble other than U1, U2, PF, and LCC,
the display returns to the main code entry menu.
2 Without canceling a trouble, the display returns to the main
code entry menu.
Main code 15
Purpose Cancel (incase of a trouble)
Function (Content) Used to cancel the self diag “U6 (09/20/21/22)”
trouble.
Section Paper feed
Item Trouble
Operation/Procedure Select with 10 digit key pad.
1 After canceling LCC trouble, the display returns to the main
code entry menu.
2 Without canceling a trouble, the display returns to the main
code entry menu.
Main code 16
Purpose Cancel (incase of a trouble)
Function (Content) Used to cancel the self diag “U2” trouble.
Section
Item Trouble
Operation/Procedure Select with 10 digit key pad.
1 After canceling U2 trouble, the display returns to the main code
entry menu.
2 Without canceling a trouble, the display returns to the main
code entry menu.
SIMULATION 14
TROUBLE CANCELLATION. (OTHERS)
ARE YOU SURE ?
1. YES
2. NO
1
SIMULATION 15
LCC TROUBLE CANCELLATION.
ARE YOU SURE ?
1. YES
2. NO
1
SIMULATION 16
U2 TROUBLE CANCELLATION.
ARE YOU SURE ?
1. YES
2. NO
1
Main code 17
Purpose Cancel (incase of a trouble)
Function (Content) Used to cancel the self diag “PF” trouble
(when copy is inhibited by the host computer).
Section Communication (RIC/MODEM)
Item Trouble
Operation/Procedure Select with 10 digit key pad.
1 After canceling PF trouble, the display returns to the main code
entry menu.
2 Without canceling a trouble, the display returns to the main
code entry menu.
Main code 21
21-1
Purpose Setup
Function (Content) Used to set the maintenance cycle.
Section
Item Spec
Operation/Procedure Used to set the maintenance cycle in an SRU
machine.
0 Maintenance display at the cycle of each control spec.
1 Maintenance display at 40K
2 Maintenance display at 50K
3 Maintenance display at 80K
4 Maintenance display at 100K
5 Maintenance display at 120K
6 No maintenance display
SIMULATION 17
PF TROUBLE CANCELLATION.
ARE YOU SURE ?
1. YES
2. NO
1
SIMULATION 21-1
MAINTENANCE CYCLE SETUP. SELECT 0-6, AND PRESS START.
0. DEFAULT 1. 40K 2. 50K 3. 80K
4. 100K 5. 120K 6.FREE
1
- !"# $%&