EasyManuals Logo

Sharp AY-X099E User Manual

Sharp AY-X099E
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
27
AH-X079E/X099E
AY-X079E/X099E
Indoor side
Standard conditions: 
Dry-bulb Temp. (˚C) Relative Humidity (%)
27
20
Cooling
Heating
47
Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%)
35
7
40
87
AY-X079E / AY-X099E
Temperature at each part and pressure in 3-way valve
Operation 
mode
Cool
(Max.)
Heat
(Max.)
Cool Heat
1
2
3
4
3-way valve
pressure
(kg/cm
2
G)
105˚C
42˚C
10˚C
16˚C
4.6
104˚C
0˚C
40˚C
2˚C
20.0
85˚C
42˚C
10˚C
10˚C
5.3
77˚C
2˚C
38˚C
1˚C
15.5
53 more than 70 50 settle 50 settle
AY-X099E
Operation 
mode
Cool
(Max.)
Heat
(Max.)
Cool Heat
1
2
3
4
3-way valve
pressure
(kg/cm
2
G)
100˚C
44˚C
11˚C
7˚C
4.5
98˚C
0˚C
41˚C
-2˚C
19.5
81˚C
42˚C
12˚C
10˚C
5.6
72˚C
2˚C
37˚C
0˚C
15.3
75 more than 80 50 settle 50 settle
AY-X079E
No.
Hz
No.
Hz
Capillary tube
O.D I.D. L
ø2.7 ø1.4 700
Capillary tube
O.D I.D. L
ø2.7 ø1.5 800
AY-X079E
AY-X099E
Dimension of Capillary tube

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AY-X099E and is the answer not in the manual?

Sharp AY-X099E Specifications

General IconGeneral
BrandSharp
ModelAY-X099E
CategoryAir Conditioner
LanguageEnglish

Related product manuals