EasyManua.ls Logo

Sharp AY-XPC12PU - Troubleshooting and Service; Unit Operation Issues; Multi-System and Indicator Troubleshooting

Sharp AY-XPC12PU
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AY-XPC12PU
3 – 6
Indoor and
outdoor
units oper-
ate.
Normal
blinking
or OFF
{{{{{Timer (Orange) 26 1 Indoor unit
room tem-
perature
thermistor
Indoor unit room
temperature
thermistor
(1) Check connector of
thermistor for
secure installation.
(1) Replace the ther-
mistor.
{{ { Operation (Green)
{ Plasmacluster(Blue)
Operation (Green)
Plasmacluster(Blue)
Operation (Green)
Plasmacluster(Blue)
(2) Check the tempera-
ture properties of
the thermistor.
(2) Replace the ther-
mistor.
{{{{{Timer (Orange) 2 Indoor unit
pipe tem-
perature
thermistor
Indoor unit pipe
temperature
thermistor
(1) Check connector of
thermistor for
secure installation.
(1) Replace the ther-
mistor.
{{ {
{
(2) Check the tempera-
ture properties of
the thermistor.
(2) Replace the ther-
mistor.
{{{{{Timer (Orange) 3 Indoor unit
valve tem-
perature
thermistor
Indoor unit valve
temperature
thermistor
(1) Check connector of
thermistor for
secure installation.
(1) Replace the ther-
mistor.
{{ {
{{
(2) Check the tempera-
ture properties of
the thermistor.
(
2) Replace the ther-
mistor.
Problem
symptom
Outdoor
unit indi-
cation
(LED1)
Indoor unit Malfunc-
tion No.
Content of diagnosis Check point Action
Lamp Main Sub Main Sub
o
*Remark
The malfunction No. is calculated using the following way.
Example)
Indoor unit lamp
o
Lamp Calculation Main Sub
168421
Timer (orange) OOOOO
Operation (Green) O O 4+1=5 5
Plasmacluster (blue) O 2 2
IPM CHECK METHOD
1. Turn off the power.
2. Make sure that the electrolytic capacitor voltage is approx. 0 V.
3. Remove all connectors of the IPM PWB.
4. Measure the resistance between terminals using a tester.
Measuring points of terminals are shown in the figure below.
Analog tester
Normal Resistance
Analog tester
Normal Resistance
--+-
TP
TN
*(Few MΩ)
TU
TN
(Few MΩ)
VTUT
WTVT
retset latigiD yb :eulav ) (* WT
IPM printed wiring board
REMOVE
REMOVE
TN
TP
TU
TV
TW
REMOVE