EasyManua.ls Logo

Sharp AY-XPC12PU - Chapter 5. Installation Instruction

Sharp AY-XPC12PU
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 – 1
AHXPC12LV
5GTXKEG/CPWCN
CHAPTER 5. INSTALLATION INSTRUCTION
AY-XPC12PU
[4].INSTALLATION DIAGRAM
[3].NOTES ON LOCATIONS
Provide as much installation space as possible for
[2].ACCESSORIES
[1].SAFETY PRECAUTIONS
1.
2.
Make a drain hose hole that will allow easy condensate water drainage.
3. both sides and above the unit.
4.
5.
Keep TV set, radio and other similar appliances at least 1 m or more away from the unit and the remote control.
6. Keep the air inlet clear of obstacles that could block incoming air
7.
The remote control may not function properly in a room equipped
lighting.
8.
Select a location that does not cause loud operation noise
and extreme vibrations.
Coating tape
(Commercially available)
2.4 inch (60 mm)
or more
2 inch (50 mm)
or more
2 inch (50 mm)
or more
Use the refrigerant pipes shown in the table below.
Pipe size Pipe thickness Thermal insulation
Liquid Side 1/4”(ø 6.35 mm)
0.03 in
(0.8 mm)
Thickness:
0.24 inch (6 mm) or thicker
Material:
Polyethylene foam
Gas Side
3/8"
(ø 9.52 mm)
The thermal insulation should cover both the gas and liquid pipes.
Installation must be made in accordance with the installation
manual by quali ed service personnel.
Incorrect work can cause electric shock, water leak,  re.
Be sure to use the attached accessories parts and speci ed parts
for installation.
Use of other parts can cause electric shock, water leak, re, the unit falling.
The appliance shall be installed and wired in accordance with
national electrical code and by quali ed personnel only.
Wrong connection can cause overheating or  re.
After installation has complete, check that there is no leakage of
refrigerant gas.
If the refrigerant gas contact with  re, it will generate toxic gas.
Ventilate the room if refrigerant gas leaks during installation.
If the refrigerant gas contact with  re, it will generate toxic gas.
Use the speci ed electrical cable.
Make sure the cable is secured in place and that the terminals are free of
any excess force from the cable. Otherwise overheating or  re may result.
Form the cable so that the control box cover, the cord holder and
cable holder are not loose.
Otherwise overheating,  re or electric shock may result.
 Tighten the are nut with a torque wrench according to the speci ed
method.
If the  are nut is tightened too hard, the  are nut may crack or break after
a long time and cause refrigerant gas leakage.
When installing the unit, take care not to enter air substance other
than the speci ed refrigerant(R410A) in the refrigerant cycle.
Otherwise, it can cause burst and injury as a result of abnormal high pres-
sure in the refrigerant cycle.
Be sure to connect the refrigerant pipe before running the compressor.
Otherwise, it can cause burst and injury as a result of abnormal high pres-
sure in the refrigerant cycle.
Ground the unit.
Incomplete ground may cause electrical shock.
Arrange the drain hose to ensure smooth drainage.
Insuf cient drainage may cause water damage to the room, furniture etc.
This room air conditioner uses refrigerant R410A.
Use refrigerant pipes,  are nuts and tools exclusively for R410A.
ITEMS
Q’ty
APPLICATION ITEMS
Q’ty
APPLICATION ITEMS
Q’ty
APPLICATION
1
Mounting plate
1
To mount the indoor
unit on the wall.
4
Dry battery
2
For the remote control.
AAA batteries.
7
Manuals
1 Operation manual
1 Installation manual
2
Long screw
5/32" x 39/32" L
(M4.5x30)
7
To x the mounting
plate.
5
Short screw
3/16" x 13/16" L
(M4x20)
3
To  x the remote
control holder.
8
Cable cover
1
To secure the cable
To  x the cable
cover.
3
Remote control
1
To control remotely.
6
Remote control holder
1
To mount the remote
control on the wall.
OPER
INS
TALL

Other manuals for Sharp AY-XPC12PU

Related product manuals