AY-XPC15PU
3-4
Problem 
symptom
Outdoor 
unit 
indication 
(LED1)
Indoor unit
Malfunction 
No.*
Content of diagnosis Check point Action
o
Lamp Main Sub Main Sub
Indoor and 
outdoor 
units do not 
operate.
10-time O O O O O Timer (Orange) 10 2 EEPROM 
error
EEPROM (outdoor) 
data error
- Replace the outdoor 
unit control PWB 
assembly.
O O Operation (Green)
O Plasmacluster (Blue)
Indoor and 
outdoor 
units do not 
operate.
11-time O O O O O Timer (Orange) 11 0 Outdoor unit 
DC fan
Outdoor unit DC fan 
rotation error
1) Check connector CN3 
of the outdoor unit DC 
fan motor for secure 
installation.
2) Check the outdoor unit 
fan motor for proper 
rotation.
3) Check fuse FUSE5.
4) Outdoor unit control 
PWB
1) Correct the installa-
tion.
2) Replace the outdoor 
unit fan motor.
3) Replace the outdoor 
unit control PWB 
assembly.
4) Replace the outdoor 
unit control PWB 
assembly.
O O O Operation (Green)
Plasmacluster (Blue)
O O O O O Timer (Orange) 1 Outdoor unit DC fan 
driver IC error
1) Check if the fan IPM 
terminal resistance 
values are uniform.
2) Outdoor unit fan motor 
continuity check.
1) Replace the outdoor 
unit control PWB 
assembly.
2) Replace the outdoor 
unit fan.
O O O Operation (Green)
O Plasmacluster (Blue)
O O O O O Timer (Orange) 2 Outdoor unit DC fan 
lock error
1) Check the outdoor unit 
fan motor for proper 
rotation.
2) 1): Normal
1) Replace the outdoor 
unit control PWB 
assembly.
2) Replace the outdoor 
unit fan.
O O O Operation (Green)
O Plasmacluster (Blue)
O O O O O Timer (Orange) 3 Detection error of DC 
fan negative rotation 
before compressor is 
driven
 (Temporary stop for DC 
fan circuit protection)
-
O O O Operation (Green)
O O Plasmacluster (Blue)
O O O O O Timer (Orange) 4 Detection error of 
inverter current for 
DC fan
- Replace the outdoor 
unit control PWB 
assembly.
O O O Operation (Green)
O Plasmacluster (Blue)
O O O O O Timer (Orange) 5 Outdoor unit DC fan 
open connector error
1) Check connector CN3 
of the outdoor unit DC 
fan motor for secure 
installation.
2) No abnormality found in 
above inspection 1).
1) Correct the installa-
tion.
2) Replace the outdoor 
unit control PWB 
assembly.
O O O Operation (Green)
O O Plasmacluster (Blue)
Indoor and 
outdoor 
units do not 
operate.
12-time O O O O O Timer (Orange) 12 0 Thermal fuse 
in terminal 
board
Thermal fuse error 
in terminal board (for 
power supply)
1) Check the thermal fuse 
in terminal board (for 
Power supply)
2) Check connector CN5 of 
the outdoor unit.
3)  1) 2): Normal
1) Replace terminal 
board for Power 
supply.
2) Correct the installa-
tion.
3) Replace the outdoor 
unit control PCB 
assembly.
O O Operation (Green)
Plasmacluster (Blue)
Indoor and 
outdoor 
units do not 
operate.
13-time O O O O O Timer (Orange) 13 0 DC 
compressor
Compressor startup 
error
1) Check the colors (red, 
white, orange) of the 
compressor cords for 
proper connection.
(PWB side, compressor 
side)
2) Check if the IPM terminal 
resistance values are 
uniform.
3) Check if outdoor main 
relay (MRY1) turns on 
and voltage of both end 
of the condenser (C10) 
has become DC290-
330V.
4)  1) 2)  3) : Normal
1) Correct the installa-
tion.
(U: Red, V: White, W: 
Orange)
2) Replace the outdoor 
unit control PWB 
assembly.
3) Replace the outdoor 
unit control PWB 
assembly.
4) Replace the com-
presso
r.
O O O Operation (Green)
Plasmacluster (Blue)
O O O O O Timer (Orange) 1 Compressor rotation 
error.
(at 120° energizing)
O O O Operation (Green)
O Plasmacluster (Blue)
O O O O O Timer (Orange) 2 Compressor rotation 
error
(at 180° energizing)
O O O Operation (Green)
O Plasmacluster (Blue)
Indoor and 
outdoor units 
operate.
O O O O O Timer (Orange) 3 Detection error of 
inverter current
Check the circuit of 
detection of inverter 
current.
Replace the outdoor 
unit control PWB 
assembly.
O O O Operation (Green)
O O Plasmacluster (Blue)