[JOB#1211]
PLU BASE Q’TY PROGRAMMING
XXXXXX: PLU code = 1 ∼ 999999
ZZ: Base quantity = 00 ∼ 99
Any PLU code should already be defined (JOB#1200) when its base
quantity is programmed.
[JOB#1212]
PLU unit price for pint sale programming (Price 1 and 2)
XXXXXX: PLU code = 1~999999
YYYYYY: Amount = 0~999999
Any PLU code should already be defined when its unit price is pro-
grammed.
MRS = 000000
[JOB#1213]
PLU pint Q’ty programming
XXXXXX: PLU code = 1~999999
Z.Z: Print quantity = 0.0~9.9
Any PLU code should already be defined when its unit price is pro-
grammed.
MRS = 0.0
[JOB#1220]
PROGRAMMING OF PLUS STOCK (ADD)
XXXXXX: PLU code = 1 ∼ 999999
YYYYYYY: Stock value = 1 ∼ 9999999
The stock value is max. 7 digits. The stock value entered is added to
the PLU stock counter.
MRS = 0.000
[JOB#1221]
PROGRAMMING OF PLU STOCK (SUB)
XXXXXX: PLU code = 1 ∼ 999999
YYYYYYY: Stock value = 1 ∼ 9999999
The stock value is max. 7 digits. The stock value entered is sub-
tracted from the PLU stock counter.
MRS = 0.000
[JOB#1222]
PROGRAMMING OF PLU STOCK (OVERWRITE)
XXXXXX: PLU code = 1 ∼ 999999
YYYYYYY: Stock value = 1 ∼ 9999999
The stock value is max. 7 digits. The stock value entered is overrited
to the PLU stock counter.
MRS = 0.000
[JOB#1223]
Programming of PLU minimum stock
XXXXXX: PLU code = 1~999999
YYYYYYY: Stock value = 1~9999999
∗ The stock value is Max. 7 digits.
MRS = 0.000
[JOB#2210]
PLU function programming
XXXXXX: PLU code = 1~999999
A: Tare table No. A
No 0
Table No. 1~9 1~9
B: Scale entry B
Inhibit 0
Enable 1
Compulsory 2
ST
1211 ZZ
TL
XXXXXX
PLU CODE
For the next PLU
0
X
X
ST
1212 YYYYYY
TL
XXXXXX
PLU CODE
For next code
No change
X
X
Next level (2times)
ST
1213 Z.Z
TL
XXXXXX
PLU CODE
For next code
0
X
X
ST1220 YYYYYYY TLXXXXXX
PLU CODE
For the next PLU
X
X
ST1221 YYYYYYY TLXXXXXX
Next code
PLU CODE
X
X
ST
1222
YYYYYYY TLXXXXXX
Next code
PLU CODE
X
X
ST
1223 YYYYYY
TL
XXXXXX
PLU CODE
For next code
0
X
X
ST
2210 AB
TL
XXXXXX
PLU CODE
For next code
0
X X
33