EasyManua.ls Logo

Sharp JH-3500U

Sharp JH-3500U
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
Specification
Model JH-3500U
Maximum system voltage (DC) 380 V
Rated input voltage (DC) 240 V
Range of operating DC voltage (DC) 110 V to 350 V
Maximum array short circuit current (DC) 10 A
Maximum operating current (DC) 22.5 A (7.5A for a DC input × 3)
Nominal output voltage (AC) 240 V
Operating voltage range (AC) 211 V to 264 V
Nominal output frequency (AC) 60 Hz
Operating frequency range (AC) 59.3 Hz to 60.5 Hz
Maximum continuous output current (AC) 15 A
Maximum continuous output power (AC) 3500 W
Rated output power 3000 W
Peak conversion efficiency (%) 92 %
Power factor More than 0.95 (more than rated output power 1/8)
Total harmonic distortion [ THD ] (%) Less than 5%
Operating temperature Solar Power -4°F
_to_104°F_(-20˚C to +40˚C)
Conditioner
Solar Power 32°F_to_104°F_(0˚C to +40˚C)
Conditioner
Display
Dimension Solar Power Width-x-Height-x-Depth_(23.62x17.72x7.56_inches)_(600×450×192_mm)
Conditioner
Solar Power Width-x-Height-x-Depth_(5.39x4.61x0.79_inches)_(137×117×20_mm)
Conditioner
Display
Weight Solar Power Approx._62_pounds_(Approx. 28 kg*)
Conditioner
Solar Power 0.5_pounds_(Approx. 0.2 kg)
Conditioner
Display
Enclosure type 3 R
Main Circuit System
Solar power conditioner system Voltage stiff current control system
Switching system PWM (pulse width modulation) system
Insulator system Built-in high frequency insulating transformer system
Electric system 1-phase 2-wire system(connected to 1-phase 3-wire system)
Protection
Grid-connected protection AC Over Voltage / Under Voltage, AC Over Frequency / Under Frequency detection
anti-islanding component (IEEE929)
Ground fault protection DC detector / interrupter
* Bracket included

Related product manuals