15
In case the warm-keeping temperature does not conform to the above temperature standard, replace the
warm-keeping TRS in accordance with the after-mentioned reparing procedure.
Warm-keeping temperature : 70
o
C to 76
o
C.
(Check this temperature immediately after opening the lid as the reading on the thermometer drops very quickly.)
Allow the bar-type thermometer to float above the pot bottom using a fragment of packing case, etc. so that the
thermometer does not come in direct contact with the inner pot.
It should be taken into account that the commercially available bar-type thermometer may give a measuring
error of one division or less.