LC-32D65E/RU, LC-37D65E/RU
3 – 8
6. Setting items (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode when set to “FIXED_ALL”, the caution is displayed for 5 seconds.
When power button on the main unit is pressed When power button on R/C is pressed
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2) Instantaneous current shutdown setting when turning off the power [SHUT DOWN MODE]
3) Volume maximum level [MAXIMUM VOLUME]
4) Volume fixed [VOLUME FIXED]
Option “VARIABLE”, “FIXED_ALL”, “FIXED_BODYKEY” or “RC RESPOND” (loop enabled)
Default “VARIABLE”
Function When set to “FIXED_ALL”, the “POWER/RECEPTION” key on the main unit or remote control is disabled.
However, the power can be turned off using the “MAIN POWER” switch.
For some models, the (MAIN) POWER switch is also disabled.
When set to “FIXED_BODYKEY”, only the “MAIN POWER” key on the main unit is disabled (the remote control is
enabled).
When selecting “RC RESPOND”, the main unit’s POWER switch toggles between ON and Standby (the same
operation as the remote control).
Key disabled when set
other than default
OFF TIMER (SLEEP)
Remarks When selecting to “FIXED_ALL”, it functions with the correspondence which isn’t done about other standby fac-
tors(see below).
No operation OFF
No signal OFF (including the power management)
Option “NORMAL” or “QUICK”
Default NORMAL
Function Scanning or recording of the digital tuner is enabled/disabled when turning off the power.
It is possible to put into the standby state instantaneously due to power off input.
Remarks When selecting “QUICK”, the function does not work for the following items (The possible method differs from model
to model: deleting the item, selection impossible, etc.)
ON TIMER, QUICK START, DIGITAL FIXED, etc.
Option 0 ~ 60 (loop disabled)
Default 60
Function The volume cannot be increased more than the adjusted value (the main unit’s speaker only).
Remarks When set to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
The volume of the headphones or monitor output is limited.
The setting is impossible when VOLUME FIXED is set other than VARIABLE.
Option “VARIABLE”, “FIXED”, “AC CTRL” or “AC/RC CTRL” (loop enabled)
Default “VARIABLE”
Function FIXED: The volume is fixed to the value adjusted in the volume fixed level.
AC CTRL: In the case of ACON, the unit starts at the volume specified in the volume fixed level.
AC/RC CTRL: The unit starts at the volume specified in the volume fixed level.
Exception In the adjustment process, the volume can be set to any level regardless of this setting.
Key disabled when set
to FIXED
VOLUME UP/DOWN (VOL+/-) [both remote control and main unit]
MUTE (MUTE) * The main unit’s keys for the menu operation are enabled.
Remarks VOLUME FIXED has priority over MAXIMUM VOLUME.
The volume of the headphones or monitor output is fixed.
The volume is not displayed when operating the above disabled keys.
VOLUME can be abbreviated to VOL.
No Power off by power button. No Power off by remote control.

Table of Contents

Other manuals for Sharp LC-32D65E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp LC-32D65E and is the answer not in the manual?

Sharp LC-32D65E Specifications

General IconGeneral
BrandSharp
ModelLC-32D65E
CategoryLCD TV
LanguageEnglish

Related product manuals