EasyManua.ls Logo

Sharp LC-39LE651E - White Balance Adjustment

Sharp LC-39LE651E
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
LC-39/50LE650
LC-39/50LE651
LC-39/50LE652
6. White Balance Adjustment
Condition:
AV MODE= Dynamic (backlight at max.).
● Select correct Inch setting (39”,50” or 60”) in “Inch setting” menu.
Adjustments reference device: Minolta CA-210
Adjustments target: x=0.274, y=0.284
High: adjustments spec ±0.001, inspection spec: ±0.002
Low: adjustments spec ±0.002, inspection spec: ±0.004
1. Press “◄ / ►” until selecting “White Balance” option.
2. Press “OK”.
3. “GAMMA” menu appears.
4. Press “◄ / ►” until selecting “MGAMMA RESET”.
5. Press “OK”, to restore default values.
6. Hold the default value for “MGAMMA G1”. (Note: next, try to get the (x, y) adjustments target, changing
“MGAMMA R1” and “MGAMMA B1” as follow).
7. Press “◄ / ►” until selecting “MGAMMA R1”.
8. Press “OK” to enter “Internal Adjustments Pattern 1”.
9. Press “◄ / ►” until you obtain the desired value.
10. Press “6” to return to previous menu.
11. Press “◄ / ►” until selecting “MGAMMA B1”.
12. Press “OK” to enter “Internal Adjustments Pattern 1”.
13. Press “◄ / ►” until you obtain the desired value.
14. Press “6” to return to previous menu.
(Note: In case of not being possible to achieve the desired (x, y) target, try to get it by changing also the
“MGAMMA G1”)
15. Press “◄ / ►” until selecting “MGAMMA R2”.
16. Press “OK” to enter “Internal Adjustments Pattern 2”.
17. Repeat from step 6 to 14 for the “MGAMMA R2” and “MGAMMA B2”.
18. Press “◄ / ►” until selecting “MGAMMA R3”.
19. Press “OK” to enter “Internal Adjustments Pattern 3”.
20. Repeat from step 6 to 14 for the “MGAMMA R3” and “MGAMMA B3”.
21. Press “◄ / ►” until selecting “MGAMMA R4”.
22. Press “OK” to enter “Internal Adjustments Pattern 4”.
23. Repeat from step 6 to 14 for the “MGAMMA R4” and “MGAMMA B4”.
24. Press “◄ / ►” until selecting “MGAMMA R5”.
25. Press “OK” to enter “Internal Adjustments Pattern 5”.
26. Repeat from step 6 to 14 for the “MGAMMA R5” and “MGAMMA B5”.
27. Press “◄ / ►” until selecting “MGAMMA R6”.
28. Press “OK” to enter “Internal Adjustments Pattern 6”.
29. Repeat from step 6 to 14 for the “MGAMMA R6” and “MGAMMA B6”.
30. Press “◄ / ►” until selecting “MGAMMACommit”.
31. Press “OK”, to save the new values.
NOTE:
For activating the W/B ag, only is necessary to send the order “Commit”. After this action, the “W” W/B ag will change
to “1”.