LC-40/46LE810E, LC-40/46LX810E
6 – 14
Table 1. Concrete flashing pattern
*2: It depends on the system. The power supply error suitable for the product is defined.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing disabled).
MONITOR ERR STBY table
Item
Expression for a rough content Expression for Details
Cause
low-speed
blinking
high-speed 
blinking
low-speed
blinking
high-speed 
blinking
Lamp system failure  Flashes once  — Flashes once  Flashes once  Lamp error
Power PWB failure Flashes twice  — Flashes twice  Flashes once  Power Error 1 AC_DET error (*2) 
(Power failure, etc.) Flashes twice  Power Error 2 UR+13.5V error (*2) 
Flashes 3 times  Power Error 3 D3.3V error (*2) 
Flashes 5 times  Panel power supply error
Main PWB failure  Flashes 3 times  — Flashes 3 times  Flashes once  Initial communication error
(Communication Flashes twice Start-up confirmation communication error
failure, etc.)  Flashes 3 times  Regular communication error
Flashes 5 times  Other communication error
Others  Flashes 4 times  — Flashes 4 times  Flashes once  Temperature error
Flashes twice  Sync error
Flashes 3 times  Notification from the main microprocessor 
(*3)
Upgrade executing  smoothness 
changes. 
— — — Version upgrading
Upgrade completion a staircase 
pattern. 
— — — Version upgrade succeeded
Upgrade failed  — Flashing
(Continuous)
— — Version upgrade failed
ROM data failure  — Flashing
(Continuous)
— — Start-up after failing version upgrade (*4)
Outline: Communication/Power failure detected by the monitor microprocessor (IC2002) is stored on EEPROM, states can be confirmed in the 
adjustment process mode.
Location: Page 1/21 of the adjustment process mode: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the page (2/21) of the 
adjustment process mode.
Display Error description
02 Start-up communication error 2  Initial communication from the main CPU is not received.
03 Start-up communication error 3  Only the initial communication is received.
04 Start-up communication error 4 Until panel information request reception
05 Start-up communication error 5 Until initialization completion reception
06 Start-up communication error 6 Until version notification transmission
07 Start-up communication error 7 Until start-up information notification transmission
08 Start-up communication error 8 Until start-up information response reception
09 Start-up communication error 9 Until time-out setting reception
0A Communication error A  REQ time-out
0B Communication error B  Restart time-out during the beginning of time acquisition start-up
0C Communication error C  Ending sequence time-out
0D Communication error D  Preset start-up time-out during completion
0E Communication error E  Download start-up time-out
0F Communication error F  Time acquisition time-out
11  Communication error H Regular communication time-out
16 Panel-related error  Lamp failure
1A Other error 2  Monitor temperature failure
1D Power supply error 1  PS_ON (AC_DET) failure
1E Power supply error 2  D_POW (DET_13V) failure
1F Power supply error 3  D_POW (DET_D3V3) failure
21 Power supply error 5  Panel power failure
23 Other error 3  Error standby request from the main CPU