LC-46D62U/LC-52D62U
5 – 11
7.4. Component 15K signal adjustment
7.5. Component 33K signal adjustment
8. Adjustment of white balance
8.1. White balance adjustment
Adjustment item Adjustment conditions Adjustment procedure
1 Adjustment 480i signal Feed the 100% color bar signal to INPUT 1 component input.
2 Auto adjustment
performance
Page 5/26 Bring the cursor on [COMP 15K ALL ADJ] and press [ENTER].
[COMP 15K ALL ADJ FINISH] appears when finished.
Adjustment item Adjustment conditions Adjustment procedure
1 Adjustment 1080i signal Feed the 100% color bar signal to INPUT 1 component input.
2 Auto adjustment
performance
Page 6/26 Bring the cursor on [HDTV ADJ] and press [ENTER].
[HDTV ADJ FINISH] appears when finished.
Adjustment item Adjustment conditions Adjustment procedure
1 Adjustment 1) Apply the following settings to the set.
AV MODE: [DYNAMIC]
Aging Time: 60 Min.
Backlight: +16
2) Connect a white balance jig and the set.
Optical measuring machine: [Minolta CA-210]
PC
RS-232C communication cable
3) Use an RS-232C command to display the screen for multipoint adjust-
ment.
Multipoint adjustment mode (MSET0001)
Adjustment value initialization (MSET0004)
Standard value 6 (WBI60928)
Standard value 5 (WBI50800)
Standard value 4 (WBI40656)
Standard value 3 (WBI30528)
Standard value 2 (WBI20352)
Standard value 1 (WBI10184)
Write setting (MSET0003)
100% white