10. Public Mode (continued)
8) Menu operation [MENU BUTTON]
9) AV position fixed [AV POSITION FIXED]
10)OSD display [ON SCREEN DISPLAY]
Option “RESPOND” or “NO RESPOND” (loop enabled)
Default “RESPOND”
Function The MENU key on the main unit and remote control is decided whether it is enabled or disabled.
Exception RESPOND
NO RESPOND
: The manu key is enabled.
: The manu key is disabled.
: All the keys are enabled regardless of this setting while entering the process mode, inspection
mode or Public Mode setting screen.
Disabled key excluding
Menu key when setting
to not default
All the direct transition keys to menu display (AUTO PRESET, MANUAL MEMORY and others)
* These keys does not exist according to the model.
Remarks When setting to “NO RESPOND
For the models with the MENU key on the main unit, menu operation is possible regardless of the setting while the ini-
tial setting when the power is turned on for the first time.
Option “VARIABLE” or “FIXED” (loop enabled)
Default “VARIABLE”
Function • VARIABLE
FIXED
: AV position is not fixed.
: AV position is fixed.
: The image/sound adjustment items in the menu are fixed in the selected state.
: When receiving “AV POSITION” of the remote control, only the actual state is displayed, and
setting is not changed.
Remarks When receiving the sound select direct keys (AV POSITION key, OPC, DOLBY key, etc.), only the actual state is dis-
played; no setting is changed.
* These keys does not exist according to the model.
The settings for the Public mode are retained after the personal data is initialized, each item for the AV position and
image/sound adjustment are not initialized.
Option “YES”, “NO” or “LIMITED” (loop enabled)
“LIMITED” is looped only in case of need (destination).
Default “YES”
Function • YES
•NO
•LIMITED
: OSD is displayed
: the following OSD is not displayed.
Registration, setting, adjustment menu, channel call, volume bar, and input select
: only a part of OSD (CH call: “New Information” etc...) is not displayed.
Key which may be
enabled
(Example of the confus-
ing key)
It is OK in the case that simple input select occur or the original state returns soon automatically.
Disabled key when set-
ting to not default
When setting to “NO”, the keys which is related to visibility of the screen and sound cannot be used.
STILL IMAGE, SCREEN DISPLAY, OFF TIMER, AV POSITION, BRIGHTNESS SENSOR, SCREEN SIZE SELECT,
AUTO PRESET, MANUAL MEMORY, IMAGE SELECT, SOUND SELECT, LANGUAGE, Closed caution
* Disabled keys dependeds on the models.
Remarks When setting to “NO”,
ON TIMER (Watching reservation) is cleared.
OFF TIMER “SLEEP” is cleared.
* These items does not exist according to the model.
When setting to “NO”,
These Displays (Version-up, Public mode setting screen, Pass Word input screen of Public
Mode, the adjustment process mode, K mark of inspection mode) are enabled regardless of
this setting.

Table of Contents

Other manuals for Sharp LC-60LE635E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp LC-60LE635E and is the answer not in the manual?

Sharp LC-60LE635E Specifications

General IconGeneral
BrandSharp
ModelLC-60LE635E
CategoryLCD TV
LanguageEnglish

Related product manuals