EasyManua.ls Logo

Sharp LM161 Series - Power Conditions for Internal Reset

Sharp LM161 Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
If the above conditions are not satisfied, the inter-
nal reset circuit will not operate normally. In such a
case, the LCD unit must be initialized by executing
a series of instructions (see the Execution by In-
structions section).
t
AS
PW
EH
t
DDR
t
cycE
t
AH
t
AH
V
OH
V
OL
DB
0
- DB
7
t
Ef
t
DHR
t
Er
V
IH
V
IL
E
V
IH
R/W
V
IH
V
IL
RS
VALID DATA
LCD27-25
Figure 6. Read Operation Timing Diagram
(For data sent from the LCD unit to the external microprocessor)
3$5$0(7(5 6<0%2/
9$/8(
81,7
0,1 0$;
(QDEOH &\FOH 7LPH W
F\F
(
QV
(QDEOH 3XOVH :LGWK +LJK /HYHO 3:
(+

QV
(QDEOH 5LVH)DOO 7LPH W
(U
W
(I
 QV
6HWXS 7 LPH 56 5:( W
$6

QV
$GGUHVV +ROG 7LPH W
$+

QV
'DWD 'HOD\ 7LPH W
''5
 QV
'DWD +ROG 7LPH W
2+5

QV
Table 10. Read Operation Timing Characteristics
(V
DD
= 5.0
±
5%, V
SS
= 0 V, Ta = 0 ~ 50
°
C)
3$5$0(7(5 6<0%2/
9$/8(
81,7
0,1 7<3 0$;
9 ROWDJH %XLOG8S 7LPH W
UFF

 PV
3RZHU2II 3HULRG W
2))

PV
Table 11. Power Conditions for Internal Reset
0.1 ms t
rCC
10 ms
t
OFF
1 ms
0.2 V0.2 V0.2 V
4.5 V
NOTE: * t
OFF
indicates Power-off Period.
V
DD
LCD27-26
Figure 7.
Dot-Matrix LCD Units
20 Display Unit User’s Manual

Related product manuals