MD-MS701H/MS702H
– 18 –
: RF side focus gain minor adjustment
 : Gain setting
: A-ATT (focus) initial setting
 : ATT setting
: B-ATT (focus) initial setting
 : ATT setting
: S gain "High" A signal offset (AINO) measurement
 : Measurement value
: S gain "High" B signal offset (BINO) measurement
 : Measurement value
: S gain "High" E signal offset (EINO) measurement
 : Measurement value
: S gain "High" F signal offset (FINO) measurement
 : Measurement value
TCRS signal offset (TCRSO) measurement
 : ATT setting
: S gain "Low" A signal offset (AINO) measurement
 : Measurement value
: S gain "Low" B signal offset (BINO) measurement
 : Measurement value
: S gain "Low" E signal offset (EINO) measurement
 : Measurement value
: S gain "Low" F signal offset (FINO) measurement
 : Measurement value
Continued from the
preceding page
R F G
SKIP UP SKIP DOWN
S A
SKIP UP SKIP DOWN
S B
SKIP UP SKIP DOWN
A H
SKIP UP SKIP DOWN
B H
SKIP UP SKIP DOWN
E H
SKIP UP SKIP DOWN
F H
SKIP UP SKIP DOWN
T H
SKIP UP SKIP DOWN
A L
SKIP UP SKIP DOWN
B L
SKIP UP SKIP DOWN
E L
SKIP UP SKIP DOWN
F L
SKIP UP SKIP DOWN
P-MODE
P-MODE
* In the specific setting display state the setting change digit changes when the [P-MODE] key is pressed.
(In case of RF side gain setting change does not occur since there is only one digit.)
• 2-digit setting
1st digit (initial value) 2nd value
• 3-rd digit setting
1st digit (initial value) 2nd value 3rd digit
P-MODE
P-MODE
P-MODE
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
L O N P
L O N R
* In laser ON state (without disc) the laser power is changed as follows when the [BASS] key is pressed.
L O N M
Play power Max. power
BASS BASS
BASS
Record power
: RF side focus gain coarse adjustment
: A-ATT (focus) tentative setting
: B-ATT (focus) tentative setting
: ABMXO measurement value display
"REPEAT" mark lighting
R F g
S a
S b
A B
DISP
DISP
* In the setting display sate the value of selected digit changes in the range of
"0h to Fh" when [VOL UP/DOWN] key is pressed.
However, the RF side gain setting changed in the range of "0h to 6h".
* When the [DISP] key is pressed, the display changes as follows.
• ABMAXO Measurement value
: RF side TCRS gain adjustment
: TCRSMIO measurement value display
"REPEAT" mark lighting
R C G
T C
DISP
DISP
• TCRSMIO Measurement value
: E-ATT (tracking) initial setting
: LPFEINO measurement value display
"REPEAT" mark lighting
: EFMIO measurement value display
"REPEAT", "1" mark lighting
S E
e i
E F
DISP
DISP
DISP
• LPFEINO/EFMIO Measurement value
: F-ATT (tracking) initial setting
: LPFEINO measurement value display
"REPEAT" mark lighting
: EFMIO measurement value display
"REPEAT", "1" mark lighting
S F
f i
E F
DISP
DISP
DISP
• LPFEINO/EFMIO Measurement value
: RF side focus gain coarse adjustment
: A-ATT (focus) initial setting
: B-ATT (focus) initial setting
: LPFABO measurement value display
"REPEAT" mark lighting
R F G
S A
S B
a b
DISP
DISP
• LPFABO Measurement value
: RF side pit section tracking gain adjustment
: Pit section adjustment COUT level setting
: RF side groove section tracking gain adjustment
: Groove section adjustment COUT level setting
: LPFEFO measurement value display
"REPEAT" mark lighting
P T G
P C H
G T G
G C H
e f
DISP
DISP
• LPFEFO Measurement value