Black Drum Counter has reached the specified life.
Cyan Drum Counter has reached the specified life.
Magenta Drum Counter has reached the specified life.
Yellow Drum Counter has reached the specified life.
Black Developer Counter has reached the specified life.
Process
Section
(Developer)
Cyan Developer Counter has reached the specified life.
Replace Colour
Developer Kit.
Magenta Developer Counter has reached the specified life.
Yellow Developer Counter has reached the specified life.
Fusing Belt Print Counter has reached the specified limit.
Replace the Fusing
Belt Kit.
Fuser Pressure Roller Print Counter has reached the
specified limit.
Replace the Pressure
Roller Kit.
Fuser Web Cleaner (Counter) has reached the specified
limit - (Pop Up FK3 Error – Web End Detected)
Replace the
Web Cleaning Kit
Primary Transfer Unit Counter has reached the
specified limit.
Replace Primary Transfer
Belt and Blade kits.
Secondary Transfer Unit Counter has reached the
specified limit.
Replace the Secondary
Transfer Belt Kit.
PTC Unit Counter has reached the specified limit.
Maintenance [All] Counter has reached specified limit
Maintenance [Colour] Counter has reached specified limit
Maintenance [All] & [Colour] Counters have reached the specified limits
Starting Powder:
The following starting powder should be applied to the relevant consumable item during maintenance:-
UKOG-0312FCZZ
[Stearic Acid]
CKOG-0345DS51 *
[Yellow Toner]
Note*: Kynar Powder [UKOG-0123FCZZ] can also be applied to the Primary Transfer Belt.
CAUTION:
Do not apply Stearic Acid (UKOG-0312FCZZ), Strontium Titanium (UKOG-0316FCZZ) or Titanium
Hydroxide (UKOG-0322FCZZ) starting powder to the Primary Transfer Belt.