EasyManua.ls Logo

Sharp MX-4141N - Page 29

Sharp MX-4141N
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SHARP
FIRMWARE RECOVERY
29
In the event of a power failure during a firmware update, the device may fail to “reboot” because of
corrupted firmware. Using the CN Update procedure described below, this function is used to
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and
various options by means of a USB memory.
MENU KEY REFERENCE:
The following five keys are used to perform firmware recovery mode. For MX-4141/5141N series, touch
the LCD panel within the area shown below to select the desired key:-
[UP] [BACK]
[DOWN] [OK]
[MENU]
CN UPDATE - Firmware Recovery Procedure:-
1. Power off the MFP and remove the Right Rear Cabinet & Screws.
2. Set the MFP PWB UPDATE DIP-SW to ON:-
Note: If a Boot failure has occurred, replace the SD Card.
3. Install the USB Memory containing the MX-4141/5141N firmware into the USB slot:-
4. Power ON the MFP device - the UPDATE PROGRAM INIT PLEASE WAIT boot menu should appear
after approx 10 seconds, followed by VERSION CHECK CONFIG: information:-.
Version Check
Conf: 00050000
Update Prog Init
Please wait

Other manuals for Sharp MX-4141N

Related product manuals