EasyManua.ls Logo

Sharp MX-C507P - Page 409

Sharp MX-C507P
562 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5028
e
Make sure that the three HVPS contacts (E) move freely and are fully extended.
E
Sensor (media type) removal
Note:
The sensor (media type) and its cable are not used on printers with serial number 75288250F2P4Z or
greater.
1
2
3
Remove the transfer module. See
“Transfer module removal” on page 371
.
Open the front door.
Remove the screw (A).
Parts removal
377