54
E
Function menu
Function
Command Direction
Parameter Reply Control/Response contents *
Monitor Lock ALCM WR 0-3 0-3 0: Off, 1: Power Button & Touch, 2: Power Button, 3: Touch
-
Remote Control Lock ALCR WR 0-2 0-2 0: Off, 1: All, 2: Except Power & Volume
All Reset RSET W 0 0: All Reset
Others
Function
Command Direction
Parameter Reply Control/Response contents *
Bright VLMP WR 0-100 0-100 -
Temperature sensor DSTA R 0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby
state
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
Temperature acquisition ERRT R Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
-
Check the resolution PXCK R - Returns current resolution in the form of hhh, vvv.
Sleep (Backlight off) BOMD W 0 Move to Sleep (Backlight off) state
1 Returns from Sleep (Backlight off) state
R 0 Sleep (Backlight off) state
1 Normal operation (Backlight on) state