S-Format
Command table
Command table
How to read the command table
Command: Command field (See page 4.)
Direction: W When the “Parameter” is set in the parameter field (see page 3), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????” or “ ?” in the
parameter field. (See page 4.)
Parameter: Parameter field (See page 4.)
Reply: Response (Returned value)
* : “●” : Indicates a command which can be used in standby state, input signal waiting state or when the
power is on.
“○” : Indicates a command which can be used in input signal waiting state or when the power is on.
“ ” : Indicates a command which can be used in standby state or when power is on.
“–” : Indicates a command which can be used when the power is on.
Power control / Input mode selection
Control/Response contents
Switches to standby state.
Resume from standby state
Input signal waiting state
Toggle change for input mode.
Control/Response contents
0: Backlight OFF, 1: Backlight ON
0: THRU, 1: PRESET, 2: USER
1: 3000K ~ 15: 10000K (500K step),
16: 5600K, 17 9300K, 18: 3200K,
19: 10500K ~ 28: 15000K (500 step)
ERR if the Color Temperature is not set to PRESET.
The contrast and offset value when the Color Temperature is set to USER.
Error if the Color Temperature is not set to USER.
Copies the value set for PRESET to the USER setting.
Increasing value, be Y(yellow).
Decreasing value, be M(magenta).
Increasing value, be B(blue).
Decreasing value, be G(green).
Increasing value, be C(cyan).
Decreasing value, be Y(yellow).