48
VT-G14
VT-G21
MECHANISM OPERATION FLOWCHART
0
5
10
15
20
25
G mechanical timing
Mode check
Cam mark
Mode detection outside
(CAM SW B D7704)
Mode detection inside
(CAM SW A D7705)
Cam graph E
60 120 180 240
300 360
CA/END
CS/EJ
19.812°
UL
81
VSR
233
PU1
179
PU2
200
PB
265
SLOW
282
FF
316
STOP
334
Cam switch
0
Mode detection outside
Mode detection inside
S sensor
S sensor
Mode detection inside
CAM SW A
Mode detection outside
CAM SW B
CS/EJ
ULD
PU1
PU2
VSR
PB
SLOW
FF
STOP
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
1
1
0
open
close
0
1
EJ
UL
FF
PU
PU2
0
1
1
0
1
1
0
0
0
0
0
1
0
0
1
00
1 or 0
1
1
1
1
1
0
1
00
1
0
0
0
000
1
0
1
0
1
0
0
0
1
0
1
00
0
0
0
0
1
1
1
1
1
VSR
PB
SLW
STP
10.354° 12.812°
MECHANISM OPERATION FLOWCHART AND TROUBLESHOOTING GUIDE