29
XG-MB50X
XR-11XC
XR-10X/S
XR-20X/S
RefNo.
1
R905
2 --
3 IC7707
4 IC7704
5 IC7701
1
2
 
Adjustmentjig(resistanceload25Ω)
Connectingcord(conversioncable)
Partname
Partname
Partcode
Partcode
PWMcontroller
RR-FZA002WJZZ
DUNTKD148WEF0
RH-iXB458WJZZ
Manufacturer
RUNTZA018WJZZ
AsahiCommunication
QCNW-E007WJZZ
SMK
VHITA78L05F-1Y
VHIM51995AF-1Y
Cementresistor
ControlPWB
5Vregulator
BallastUnit
LampCable
(QCNW-D573WJQZ)
AdjustmentJig
(RU N TZA 018WJZZ)
C onnectingC ord
(Q C N W -E007WJZZ)
XG-MB50X
XR-11XC
XR-10S/X
XR-20S/X
Projector
TP1
TP2
−
+
[Adjustmentofballastunitoutputpower(lamppower)]
1.Listofpartsrequiringadjustment
Whenreplacingthefollowingparts,adjusttheballastunitoutputpower(lamppower).
2.Adjustmentjigs
Thefollowingjigsarerequiredforadjustingtheballastunitoutputpower(lamppower).
3.Ballastunitoutputpower(lamppower)adjustmentmethod
Adjusttheballastunitoutputpower(lamppower)inthefollowingmethod.
[Adjustmentmethod]
(1)Unplugtheballastunitlampcable(QCNW-D573WJQZ)oftheXR10/20projectorfrom
 thelampandconnectthecabletotheconnectingcord(QCNW-E007WJZZ).
(2)Connecttheconnectingcord(QCNW-E007WJZZ)totheadjustmentjig
 (RUNTZA018WJZZ).
(3)ConnectTP1oftheadjustmentjig(RUNTZA018WJZZ)tothenegativeterminalofthe
 testerandTP2tothepositiveterminal.
(4)TurnontheXR10/20projector.
(5)Agetheprojectorfor60secondsormore.
(6)Adjustthevolumeresistor(R7728)oftheballastcontrolPWB(DUNTKD148WEF0)so
 thatthevoltageofthetesterreaches83±0.5V.
Adjustmentvalue:83±0.5V
[Cautions]
(1)Cautionforelectricshock:DonottouchthetestpointsTP1andTP2oftheadjustment
 jigwhensupplyingpowersinceahighvoltageandlargecurrentisappliedtothem.
(2)Cautionforheat:Becarefulthattheresistanceloadoftheadjustmentjigproducesahigh
 temperaturewhensupplyingpower.
(3)Connectionofthelampcable:Checkthatthelampcableandconnectingcord(QCNW-E
 007WJZZ)areconnectedsecurely.
 Poorconnectionmaycausesmokingorignitionduetoarcdischarge.
[Settingmethod]
Tester
(Voltage)