SECTION 5 – SPECIFICATIONS
5-2
Model SX21
Hydrostatic
Model SX24
Hydrostatic
COOLING SYSTEM
Type Pressurized Liquid with
Recirculating Bypass
Pressurized Liquid with
Recirculating Bypass
Water Pump:
Type Centrifugal Centrifugal
Drive V – Belt V – Belt
Belt
Deflection 5 – 10 mm when 5 kg thumb
pressure is applied midway
between pulleys
5 – 10 mm when 5 kg thumb
pressure is applied midway
between pulleys
Fan Diameter 330 mm 330 mm
Number of Fan Blades 7 7
Thermostat:
Start to Open 82ºC 82ºC
Fully Open 95ºC 95ºC
Radiator Cap 90 kPa 90 kPa
ELECTRICAL SYSTEM
Main system Protection 40A Slow – Blow fuse 40A Slow – Blow Fuse
Number of fuses for Circuit
Protection
3
3
Alternator 12V/40A 12V/40A
Battery Type 12V, 36 amp. 46B24R 12V, 36 amp 46B24R
Start HP (kw) Rating 1.6 (1.2) 1.6 (1.2)
Starting Motor Pre-Engaged Reduction Pre-Engaged Reduction
FUEL SYSTEM
Fuel Type
Type of Fuel to Use if
Above 4.5ºC
No.2-Diesel, Cetane Rating:
Minimum 40
No. 2-Diesel, Cetane Rating:
Minimum 40
Type of Fuel to Use if
Below 4.5ºC
No.1-Diesel, Cetane Rating:
Minimum 40
No. 1-Diesel, Cetane Rating:
Minimum 40
Injection Pump
Type In-Line In-Line
Timing 23ºBTDC 23ºBTDC