20
Between analog output or communication and other input/output terminals 500V AC 1 minute or 600V AC 1 second
Resistance to vibration Frequency 10~ 55~10Hz, amplitude 0.75mm (one side amplitude )・・・100m/S
Direction 3 directions
Sweep speed 1 octave/minute (about 5 minutes for both-way/cycle) Number of sweep 10 times
Case material PPO or PPE
Case color Light gray (Mansel value 3.73B7.77/0.25)
Outside dimension MAC3 A H96×W96×D69mm (depth in panel 65mm)
MAC3 B H96×W48×D66mm (depth in panel 62mm)
MAC3C : H72×W72×D62mm (depth in panel 62mm)
MAC3 D H48×W48×D66mm (depth in panel 62mm)
Thickness of applied panel 1.2-2.8mm
Size of attachment hole
MAC3A H92×W92mm Attachment hole size of horizontal plural proximity attachment W(96×N-4) mm H92mm
MAC3B H92×W45mm N=number of equipment W(48×N-3) mm H92mm
MAC3C : H68×W68mm W(72×N-4) mm H68mm
MAC3D H45×W45mm W(48×N-3) mm H45mm
Weight MAC3A About 220g :
MAC3B About 160g
MAC3C : About 160g
MAC3D About 120g
Isolation Except for input, system and contact, all control output are no-isolation
Between event output EV1 and EV2 1 is not insulated
Others are basic insulation or functional insulation.
Refer to the following insulation block chart.
Insulation block chart
Basic I nsulation Functional insulation Not insulated
Power supply
Control output 1 (contact)
Measurement input (PV) Control output 1 (a voltage pulse / current)
Control output 2 (contact)
External control input 1 (DI1) System Control output 2 (voltage pulse / current)
External control input 2 (DI2) Event output 1 (EV1)
External control input 3 (DI3) Event output 2 (EV2)
External control input 4 (DI4) Event output 3 (EV3)
Current transformer 1 (CT1) Analog output (AO)
Current transformer 2 (CT2) Communication