EasyManuals Logo

Shimax MAC3 Series User Manual

Default Icon
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
-5.
3-5.3-5.
3-5.Terminal arrangement diagram
3-5. Terminal arrangement plan of MAC3A and MAC3B
OUT2/EV3/DI4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
DI1
DI2
DI3
AO
+
-
EV2
EV1
INPUT
L
N
POWER
OUT1
90-264V AC
50/60Hz 9VA
COM
+
-
CT1
CT2
+
A
B
B
RS-485
+
+
CONTACT:240V AC 2A
SSR DRIVE:12V DC 20mA
CURRENT:4-20mA DC
CONTACT:240V AC 2A
SSR DRIVE:12V DC 20mA
CURRENT:4-20mA DC
EV3:240V AC 2A
240V AC 2A
240V AC 2A
L +
N -
POWER
21.6-26.4V DC
4W
50/60Hz 6VA
21.6-26.4V AC
COM
VOLTAGE:0-10V DC
VOLTAGE:0-10V DC
Note: If input type is thermocouple or voltage, errors may occur when terminal 11 and
terminal 12 terminal are short-circuited
Terminal arrangement plan of MAC3C
1
2
3
4
5
6
10
11
12
13
14
15
16
17
18
EV2
EV1
DI1
DI2
DI3
AO
+
-
COM
+
-
CT1
CT2
L
N
POWER
OUT1
90-264V AC
50/60Hz 9VA
OUT2/EV3/DI4
INPUT
+
A
B
B
CONTACT:240V AC 2A
SSR DRIVE:12V DC 20mA
CURRENT:4-20mA DC
+
+
CONTACT:240V AC 2A
SSR DRIVE:12V DC 20mA
CURRENT:4-20mA DC
EV3:240V AC 2A
240V AC 2A
240V AC 2A
COM
7
8
9
19
20
21
22
23
24
25
26
27
L +
N -
POWER
21.6-26.4V DC
4W
50/60Hz 6VA
21.6-26.4V AC
VOLTAGE:0-10V DC
VOLTAGE:0-10V DC
Note: If input type is thermocouple or voltage, errors may occur when terminal 8 and
terminal 9 terminal are short-circuited
Terminal arrangement plan of MAC3D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
EV2
EV1
DI1
DI2
DI3
AO
+
-
COM
+
-
CT1
CT2
L
N
POWER
OUT1
90-264V AC
50/60Hz 9VA
OUT2/EV3/DI4
INPUT
+
A
B
B
CONTACT:240V AC 2A
SSR DRIVE:12V DC 20mA
CURRENT:4-20mA DC
+
+
CONTACT:240V AC 2A
SSR DRIVE:12V DC 20mA
CURRENT:4-20mA DC
EV3:240V AC 2A
240V AC 2A
240V AC 2A
L +
N -
POWER
21.6-26.4V DC4W
50/60Hz 6VA
21.6-26.4V AC
COM
VOLTAGE:0-10V DC
VOLTAGE:0-10V DC
Note: If input type is thermocouple or voltage, errors may occur when terminal 5 and
terminal 6 terminal are short-circuited
4.
4.
4.. Description of front panel
4-1.
4-1.4-1.
4-1.Names of front panel.
MAC3 6×96size front AC3C72×72size front
AC3D 48×48size front
MA3B48×9size front
4-2. Explanation of front panel section
: Display of measured value (PV) (red)
Measured value (PV) and type of setting is displayed on each setting screen.
: Display of target value (SV) (green)
Target value and set value are displayed on each setting screen.
Monitor LED
(1) RUN monitor LED RUN (green)
If RUN is performed with RUN key, operation mode1 screen, external control input (DI), and
communication, it lights up, and put out by standby (reset). It blinks, if a manual output is
chosen in output monitoring screen or external control input (DI).
(2) Program functional monitor LED PRG (green)
Lights up at the time of program control's standby or flat part control. Puts out at the time of
FIX control selection.
(3) Auto tuning operation monitor LED AT (green)
If AT is chosen in ON or external control input (DI), blinks during AT execution. Lights up
when AT is on standby, and puts out with AT automatic termination or release.
(4) control out put 1 monitor LED OUT (green)
At the time of a contact or a voltage pulse output, the it lights up with ON and lights off with
OFF. Lights off with 0% power output, and lights up with 100% power.
And blinks in intermediate ratio.
(5) Event output monitors LED EV1 and EV2 (yellow)
Lights up when the allotted event output turns to ON.
(6) Control out put 2/event output 3 monitors LED OUT2/EV3 (yellow)
When control output 2 is chosen, it operates like control output 1 monitor LED does.
When event output 3 is chosen, it operates like event output monitor LED does.
Key-switch section
(1)
(MENU)key
Press this key to move onto the next screen among the screens.
Press
(MENU) key for three seconds on the basic screen, then it jumps to the
lead screen of Mode 1. Press
key for three seconds on the lead screen of each
Mode screens, then it jumps to the basic screen.Press
key for three seconds on
the lead screen of FIX or PROG, then it jumps to the basic screen.When a
program control option is added, press
(MENU) key for three seconds on the
screen of operation mode 2, then it jumps to the screen of operation Mode 1.
(2)
(DOWN)key
Press
(DOWN) key one time, and the shown value decreases by one numerical value.
One time press of
key decreases by one numerical value. By pressing the key
continuously, the value as well consecutively decreases. A decimal point of the smallest digit
blinks at this time. This shows that a setting change is in progress.In PROG, used as a shift key
between each step setting screens(Steps 1-25) ,lead screen.Also used as a shift key between
lead screen in each mode screens.
(3 )
(UP) key
Press
(UP) key one time, and the shown value increases by one numerical value.
By pressing continuously, the value By pressing the key continuously, the value consecutively
increases. A decimal point of the smallest digit blinks at this time. This shows that a setting
change is in progress. In PROG, used as a shift key between each step setting screens (Steps
1-25), lead screen. Also used as a shift key between lead screen in each mode screens.
(4)
(ENTRY/REGISTER)key
The setting data changed on each screen is determined (the decimal point of the minimum
digit is also lighted off).
When a program control option is added, press
(ENT) key for three seconds on the screen
of operation mode 1, then it jumps to the screen of operation Mode 2.
Press
key for 3 seconds on the output monitoring screen,then the shift between manual
output and automatic output is carried out.
Press the key for 3 seconds on the basic screen, then it shifts to FIX or PROG head screen.
Push at FIX-PROG and each mode screens' lead screen, then shifts to setting screen.
(5)
(RUN OPERATION/STOP)key
Push for 3 seconds at STBY (control stop), then FIX or PROG control starts.
Push for 3 seconds while FIX or PROG is in operation, then control is stopped.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shimax MAC3 Series and is the answer not in the manual?

Shimax MAC3 Series Specifications

General IconGeneral
BrandShimax
ModelMAC3 Series
CategoryController
LanguageEnglish

Related product manuals