Models:WQ(D)WQ(D)-L1WQ(D)-L2WQKWVSDDWE
WQDSWQ(D)AS-CBWQ-QGWQ(D)-4P
Vortex Type Micro Clean Water Pump
SERVICE MANUAL
SUBMERSIBLE ELECTRIC SEWAGE PUMP

Questions and Answers

  • K
    kathymedinaAug 4, 2025
    What to do if my SHIMGE WQ(D stops running suddenly?
    • B
      Brittany MccoyAug 4, 2025
      If your SHIMGE Water Pump suddenly stops, check if the switch is off or the fuse is burnt out and adjust the lift or supply voltage to meet requirements. Also, clear away any foreign matters that may be jamming the impeller. If the stator winding is burnt out, it needs to be rewound for overhaul.
  • K
    Kevin SmithAug 11, 2025
    Why is my SHIMGE WQ(D Water Pump having difficulty in starting?
    • J
      Jerry VegaAug 12, 2025
      Your SHIMGE Water Pump might be hard to start because the supply voltage is too low; adjust it to ±10% of the rated value. Other potential causes include phase loss (check the switch outlet, cable, and plug), a jammed impeller (fix the jammed part), excessive voltage drop in the cable (use a reasonable cable), or a burnt-out stator winding (rewind for overhaul).
  • M
    Michelle LyonsAug 19, 2025
    How to fix low water output in SHIMGE WQ(D Water Pump?
    • B
      Brandi ReyesAug 19, 2025
      If your SHIMGE Water Pump has low water output, it could be due to several reasons. The lift might be too large; use the pump within its usable range. The mesh enclosure may be blocked; clear away water plants and foreign matter. The impeller could be worn; replace it. The immersion depth might be too shallow, causing air to be sucked in; adjust the depth to be no less than 0.5m. Alternatively, the impeller might be reversing; exchange any two of the three phases.
  • S
    Sandra DunnAug 27, 2025
    Why is my SHIMGE WQ(D Water Pump stator winding burnt out?
    • W
      washingtonstephenAug 27, 2025
      The stator winding in your SHIMGE Water Pump may be burnt out due to several reasons: phase loss or prolonged running time, water leaks damaging the mechanical seal and causing short circuits, a jammed impeller, frequent pump startups or running without water for too long, or pump overload. To fix this, eliminate the faults, remove the winding and insert the winding again according to the original technical requirements, and apply insulating paint by impregnating and drying, or send it to the maintenance company for repair.

Summary

Product Introduction

Operating Conditions

Structural Diagrams

Installation & Use and Matters Needing Attention

Pre-Installation and Initial Checks

Verify transport condition and insulation resistance before operation.

Wiring and Electrical Safety

Correct wiring, leakage protectors, overload devices, and safe contact.

Test Run and Rotation Check

Perform short test runs to verify pump rotation direction.

Delivery Pipe Connection

Proper methods for connecting delivery pipes to the pump's outlet joint.

Cable Handling and Lifting Safety

Prohibits cable misuse and specifies safe lifting rope usage.

Immersion Depth and Water Level

Specifies maximum immersion depth and minimum water level for normal operation.

Safety Warning Signs

Placement of warning signs to prevent accidents at the work site.

Thermal Protector Operation

Behavior of thermal protectors and actions for frequent protection activation.

Lift and Pipe Diameter Guidelines

Use pumps within specified lift ranges and match pipe diameters.

Motor Cavity Requirements

Motor cavity is dry structure, not to be filled with oil or water.

Oil Chamber and Leakage Precautions

Information on oil chamber oil type and handling potential oil leakage.

Safety When Touching Pump

Emphasizes disconnecting power before adjusting or touching a running pump.

Cable Joint Sealing Procedures

Proper sealing of cable joints and plugs to prevent water seepage.

Maintenance

Insulation Resistance Check

Regular checks of insulation resistance between winding and enclosure.

Pump Maintenance Schedule

Schedule for sending pumps to qualified maintenance stations after 2000 hours.

Long-Term Storage Procedures

Procedures for cleaning, drying, and anti-rust treatment when the pump is not in use.

Troubleshooting

SHIMGE WQ(D) Series Specifications

General IconGeneral
ModelWQ(D) Series
TypeSubmersible Sewage Pump
Protection ClassIP68
Voltage220V - 380V
Outlet Diameter50 mm - 150 mm
Liquid Temperature0°C - 40°C
MaterialCast Iron
ApplicationIndustrial Wastewater
Frequency50Hz