21
Temp range 16℃ 31℃
(St+3)℃
(St+2)℃
Setting temp St
Compressor ON
Compressor OFF
When Rt≤St+2℃,compressor ON.
When Rt≥St+3℃,compressor OFF
When St+2℃<Rt<St+3℃,and the compressor OFF≥6min,the compressor ON.
Auto operation
Timer
You can set timer to on/o in 24 hours
Timer on
Mode
Cooling(including auto)
Heating(including auto)
Dry(including auto)
Condition Start time
Rt-St≥2℃
St-Rt≥3℃
45min before setting time
60min before setting time
On setting time
~
Setting temp range 19℃ 29℃
~
Room temp before operation Auto operation mode Auto temp
21℃<tr<27℃
tr≥27℃
tr≤21℃
cooling
dry
heating
27℃
Room temp tr
21℃
After operation for 15 minutes,if you press "too warm"or"too cool"button,you can adjust the setting temp ±2℃.
Once start a mode,it will cost 2 hours,then you can choose another one.
≥6min
Heating operation
System control