Cooling capacity
6
7000Btu 9000Btu 12000Btu 18000Btu 24000Btu
Model
KFR-23GW KFR-26GW KFR-34GW KFR-50GW KFR-70GW
Heating capacity
Rated power input
Cooling
Heating
Rated current
Cooling
Heating
Power
Air ow
(indoor/high speed)
Noise(indoor/outdoor)
Refrigerant(R407C)
Connecting pipe
Liquid
Gas
Connecting wire
Power wire
Drain hose
Indoor
Outdoor
Dimension(W×H×D)
Indoor
Outdoor
Weight(indoor/outdoor)
2600
8877
5000
17071
7000
23899
2900
9901
5500
18778
7000
23899
980
890
1950
2000
2600
2400
220V/230~50Hz 220V/230~50Hz 220V/230~50Hz
500 800 900
≤39/50 ≤46/57 ≤48/60
830 1650 2300
3×1.0+2×0.75 3×1.0+2×0.75 3×1.5+2×0.75 3×1.5+2×0.75 3×1.5+2×1.0
3×1.0/10A 3×1.0/10A 3×1.5/10A 3×1.5/16A 3×2.5
I. dφ16 I. dφ16 I. dφ16 I. dφ20
810×280×185
760×528×256
1000×325
×190
850×605×290
1090×330×220
860×730×310
10.5/29.5 15/51 16.5/61
2300
7853
2500
8535
880
890
4.2
4.0
450
660
≤38/49
I. dφ16
745×250×190
630×545×255
810×280×185
760×528×256
8.5/25 10.5/38.5
4.6
4.3
6.3
6.8
9.0
9.5
12.1
11.5
1250
≤41/51
500
1340
1470
1400
4100
11608
3400
Btu/h
W
A
db(A)
g
Btu/h
W
W
inch
Kg
2
mm
2
mm
mm
mm
m /h
3
220V/230~50Hz 220V/230~50Hz
1/4
"
1/4
"
1/4
"
1/4
"
3/8
"
5/8
"
1/2
"
3/8
"
3/8
"
1/2
"
Technical specications
Heat pump
Refrigerant R407C
Note:
Rated cooling capacity under below conditions:
Indoor temp:27℃DB,19℃WB;Outdoor temp:35℃DB,24℃WB.High speed;4-meter connecting pipe.
Rated heating capacity under below conditions:
Indoor temp:20℃DB;Outdoor temp:7℃DB,6℃WB.High speed;4-meter connecting pipe.
We get the noise under heating mode meantime.The fan runs at high speed.
3
1
2